AI Paper Atlas

Research map / Label-efficient and robust learning / Noisy labels

Mask-guided Semantic Alignment: Robust Learning with Noisy Labels via Temporal Attention Stability

Yubo Nian, Can Gao

ECCV 2026 · Label-efficient and robust learning › Noisy labels · approach: Noisy cross-modal hashing and multi-label · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add ATC (attention temporal consistency) sample selection (ablation)baseline LNL framework · CIFAR-10 (sym 90% noise)test accuracy: 86.8 -> 94.6Improved
add ATC sample selection (ablation)baseline LNL framework · CIFAR-100 (sym 90% noise)test accuracy: 44.0 -> 49.6Improved
add ATC sample selection (ablation)baseline LNL framework · CIFAR-10 (sym 20% noise)test accuracy: 97.1 -> 97.1No clear effect
add AAM (adaptive attention masks) on top of ATC (ablation)ATC model · CIFAR-100 (sym 80% noise)test accuracy: 70.5 -> 72.3Improved
add AAM on top of ATC (ablation)ATC model · CIFAR-100 (sym 90% noise)test accuracy: 49.6 -> 53.3Improved
add MFA (mask-guided feature alignment) on top of ATC+AAM (ablation)ATC+AAM model · CIFAR-100 (sym 90% noise)test accuracy: 53.3 -> 55.6Improved
add MFA on top of ATC+AAM (ablation)ATC+AAM model · CIFAR-100 (sym 80% noise)test accuracy: 72.3 -> 73.3Improved
add MFA on top of ATC+AAM (ablation)ATC+AAM model · CIFAR-10 (sym 90% noise)test accuracy: 94.8 -> 95.1Improved
use full method instead of DULC under extreme noiseOurs vs DULC · CIFAR-100 (sym 90% noise)test accuracy: 52.8 -> 55.6Improved
use full method instead of DULC under extreme noiseOurs vs DULC · CIFAR-10 (sym 90% noise)test accuracy: 93.5 -> 95.1Improved
use full method instead of best baseline CCLRLOurs vs CCLRL · Animal-10Naccuracy: 89.7 -> 90.8Improved
vary mask ratio mu (optimum at 0.6) (ablation)AAM · CIFAR-100 (sym 80% noise)test accuracy: peaks at 73.3% when mu = 0.6Mixed

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy