Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace confidence sampling with FuDU fuzzy dual-uncertainty samplingRT-DETR streaming AL · Nuclear fuel rod defectsmean mAP50: 87.2 -> 92.2Improved
use FuDU instead of confidence across backbones and detection headsSwin, ViTDet, DEIM, MR-DETR, MI-DETR · Nuclear fuel rod defectsmean mAP50: 87.3 -> 91.6 (Swin); 86.6 -> 93.2 (MI-DETR)Improved
set prototype count k to 50 rather than 10 (ablation)PGUQ · Nuclear fuel rod defectssampling ratio: 40.5% -> 15.4% with mAP 92.0 -> 92.2Improved
set prototype count k to 50 rather than 100 (ablation)PGUQ · Nuclear fuel rod defectsmean mAP50: 88.5 -> 92.2Improved
learnable end-to-end prototypes instead of re-clustering each round (ablation)PGUQ · Nuclear fuel rod defectsmean mAP50: 90.8 -> 92.2Improved
prototype distance instead of reconstruction-based global uncertainty (ablation)PGUQ · Nuclear fuel rod defectsmean mAP50: 89.7 (CD), 88.8 (FAE) -> 92.2Improved
add defect uncertainty Ud to global uncertainty (ablation)FuDU · Nuclear fuel rod defectsmean mAP50: 89.6 -> 92.2Improved
add localization entropy weight (w2=2) with classification entropy (ablation)DeUE · Nuclear fuel rod defectsmean mAP50: 90.2 -> 92.2Improved
increase classification entropy weight to 2 (ablation)DeUE · Nuclear fuel rod defectsmean mAP50: 91.7 -> 89.8Hurt
increase localization weight to 4 (ablation)DeUE · Nuclear fuel rod defectssampling ratio: 15.4% -> 17.3% (mAP 92.2 -> 92.1)Hurt
fuzzy inference sampling instead of hard threshold (ablation)FuDU · Nuclear fuel rod defectsmean mAP50 / ratio: 92.0 -> 92.2; P 88.2 -> 95.1Improved
fuzzy inference instead of sigmoid mapping (ablation)FuDU · Nuclear fuel rod defectssampling ratio: 23.4% -> 15.4%Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy