AI Paper Atlas

Research map / Video / Action recognition

Gen2Balance: Generative Balancing for Long-Tailed Video Action Recognition

Prajwal Gatti, Simon Jenni, Fabian Caba, Dima Damen

ECCV 2026 · Video › Action recognition · approach: Disentangled action recognition · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add generated videos with plain CE (ablation)CE on K100-LT · K100-LT (B=330)avg class accuracy: 54.8 -> 50.8Hurt
use Balanced Softmax loss with generated data (ablation)CE on augmented data · K100-LT (B=330)avg class accuracy: 50.8 -> 61.3Improved
add stage 2 fine-tuning on real data (ablation)BSCE stage 1 (N+N') · K100-LT (B=330)avg class accuracy: 61.3 -> 70.6Improved
use real class frequencies for BSCE margins instead of augmented frequencies (ablation)two-stage Gen2Balance · K100-LT (B=330)few-shot accuracy: 61.0 -> 62.1Improved
train stage 1 longer (135 epochs) instead of two stages (ablation)BSCE real freq · K100-LT (B=330)avg class accuracy: 67.8 -> 67.9No clear effect
add diversified prompts over naive prompting (ablation)WAN generation · K100-LT 10 ablated classesaccuracy on 10 classes: 37.3 -> 44.9Improved
add action profile (ablation)WAN generation · K100-LT 10 ablated classesaccuracy on 10 classes: 44.9 -> 47.2Improved
add in-context exemplars to action profile (ablation)WAN generation · K100-LT 10 ablated classesaccuracy on 10 classes: 47.2 -> 49.8Improved
use generated videos instead of web-retrieved real videos (ablation)augmentation source · K100-LT (B=330)avg class accuracy: 66.9 -> 70.9Improved
use generated videos instead of generated images (ablation)augmentation source · K100-LT (B=330)avg class accuracy: 68.0 -> 70.9Improved
use naive templated prompts (ablation)WAN generation · K100-LT (B=330)avg class accuracy: 70.9 -> 65.1Hurt
raise filling threshold from B=330 to B=990 (ablation)Gen2Balance · K100-LTavg class accuracy: 70.9 -> 72.6Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy