Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| replace deterministic MeanFlow with SC-Flow (Brownian bridge plus spectral corrector) | MeanFlow · MRI to Abeta-PET (ADNI) | PSNR: 22.16 -> 24.72 | Improved |
| replace deterministic MeanFlow with SC-Flow | MeanFlow · MRI to FDG-PET (NACC) | PSNR: 21.96 -> 27.41 | Improved |
| one-step SC-Flow instead of 100-NFE multi-step models | SC-Flow · MRI to Tau-PET (A4) | MAE: PASTA 2.84 -> 2.38 | Improved |
| use SC-Flow synthetic images for downstream AD classification | ResNet50 · NACC-FDG diagnosis | F1: 60.32 -> 71.77 | Improved |
| use SC-Flow synthetic images for downstream AD classification | SeResNext · A4-Tau diagnosis | AUC: 46.15 -> 70.19 | Improved |
| SC-Flow versus Pix2Pix on NACC-FDG AUC | SC-Flow · NACC-FDG diagnosis | AUC: 82.29 -> 81.25 | Hurt |
| use 24 radial bins instead of very fine bins (96) or too coarse (ablation) | Spectral Consistency Corrector · ablation (numbers not in extract) | accuracy | Improved |
| add spectral consistency corrector and Brownian bridge diffusion term (ablation) | SC-Flow · ablation (numbers not in extract) | translation accuracy | Improved |
Closest papers by meaning
- MAISI-v2: Accelerated 3D High-Resolution Medical Image Synthesis with Rectified Flow and Region-specific Contrastive Loss (AAAI 2026 · similarity 0.88)
- Knowledge Transfer Scaling Laws for 3D Medical Imaging (NeurIPS 2026 · similarity 0.85)
- STREAM: Stochastic Riemannian Flow Matching with Anisotropic Decoder for Digital Histopathology Image Generation (NeurIPS 2026 · similarity 0.84)
- MedFlowSeg: Flow Matching for Medical Image Segmentation with Frequency-Aware Attention (NeurIPS 2026 · similarity 0.84)
- Improving Progressive Generation with Decomposable Flow Matching (NeurIPS 2025 · similarity 0.84)
- VCT: Training Consistency Models with Variational Noise Coupling (ICML 2025 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.