| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add tz depth target to predicted fields (ablation) | SSD-AF-2D · HMD Controller test set | uv position MAE (pixels): 12.41 -> 10.23 | Improved |
| use stacked stereo image pair as input and predict keypoint in both images (ablation) | SSD-AF-3D · HMD Controller test set | uv position MAE (pixels): 10.23 -> 8.45 | Improved |
| use stacked stereo input with both-image predictions (ablation) | SSD-AF-3D · HMD Controller test set | xyz position MAE (m): 0.0493 -> 0.0335 | Improved |
| use stacked stereo input with both-image predictions (ablation) | SSD-AF-3D · HMD Controller test set | detection mAP @0.5 IOU: 0.5131 -> 0.7767 | Improved |
| add tz depth target to predicted fields (ablation) | SSD-AF-2D · HMD Controller test set | detection mAP @0.5 IOU: 0.5180 -> 0.5131 | No clear effect |
| use stereo pair instead of single image (ablation) | SSD-AF-3D · HMD Controller test set | mobile CPU latency (ms): 30.649 -> 31.768 | No clear effect |
| replace regression with discrete 27-bin orientation classification (ablation) | orientation prediction · HMD Controller test set | orientation bin mAP: 0.3627 -> 0.6538 | Improved |
| use 512 bins instead of 27 bins (ablation) | SSD-AF-Binned · HMD Controller test set | bin classification mAP: 0.6538 -> 0.3627 | Hurt |
| use quaternion instead of Euler orientation encoding (ablation) | SSD-AF-Stereo6D · HMD Controller test set | pitch MAE (radians): 1.5840 -> 1.4790 | Improved |
| use quaternion instead of Euler orientation encoding (ablation) | SSD-AF-Stereo6D · HMD Controller test set | xyz position MAE (m): 0.0448 -> 0.0521 | Hurt |
| bin orientation per axis instead of regressing quaternion (ablation) | SSD-AF-Stereo6D-Quat · HMD Controller test set | pitch MAE (radians): 1.4790 -> 0.8594 | Improved |
| predict 4 keypoints instead of quaternion regression (ablation) | SSD-AF-Stereo6D-Quat · HMD Controller test set | pitch and roll MAE (radians): 1.4790 -> 1.108; 0.6653 -> 1.203 | Mixed |
Closest papers by meaning
- Instance Tracking in 3D Scenes from Egocentric Videos (CVPR 2024 · similarity 0.84)
- FRAME: Floor-aligned Representation for Avatar Motion from Egocentric Video (CVPR 2025 · similarity 0.84)
- HOT3D: Hand and Object Tracking in 3D from Egocentric Multi-View Videos (CVPR 2025 · similarity 0.83)
- EMHI: A Multimodal Egocentric Human Motion Dataset with HMD and Body-Worn IMUs (AAAI 2025 · similarity 0.82)
- Ego4o: Egocentric Human Motion Capture and Understanding from Multi-Modal Input (CVPR 2025 · similarity 0.82)
- HMD-Poser: On-Device Real-time Human Motion Tracking from Scalable Sparse Observations (CVPR 2024 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.