Research map / Label-efficient and robust learning / Test-time adaptation
Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-Learner
Eugene Lee, Evan Chen, Chen-Yi Lee
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add meta-training (inductive inference) (ablation) | end-to-end baseline · MAHNOB-HCI | MAE (bpm): 7.47 -> 7.42 | No clear effect |
| add prototypical distance minimizer at test time (ablation) | Meta-rPPG · MAHNOB-HCI | MAE (bpm): 7.42 -> 6.05 | Improved |
| add synthetic gradient generator at test time (ablation) | Meta-rPPG · MAHNOB-HCI | MAE (bpm): 7.42 -> 3.88 | Improved |
| combine proto and synth transductive gradients (ablation) | Meta-rPPG (synth only) · MAHNOB-HCI | MAE (bpm): 3.88 -> 3.01 | Improved |
| add prototypical distance minimizer at test time (ablation) | Meta-rPPG · UBFC-rPPG | MAE (bpm): 13.23 -> 7.82 | Improved |
| add synthetic gradient generator at test time (ablation) | Meta-rPPG · UBFC-rPPG | MAE (bpm): 13.23 -> 9.11 | Improved |
| combine proto and synth transductive gradients (ablation) | Meta-rPPG (proto only) · UBFC-rPPG | MAE (bpm): 7.82 -> 5.97 | Improved |
| add meta-training without adaptation (ablation) | end-to-end baseline · UBFC-rPPG | MAE (bpm): 12.78 -> 13.23 | Hurt |
| adapt only feature extractor rather than jointly with rPPG estimator (ablation) | Meta-rPPG · MAHNOB-HCI | MAE (bpm): 4.25 -> 3.01 | Improved |
| use 10 adaptation steps instead of 30 at test time (ablation) | Meta-rPPG (proto+synth) · MAHNOB-HCI | MAE (bpm): 6.20 -> 3.01 | Improved |
| increase adaptation steps from 5 to 10 (ablation) | Meta-rPPG (proto+synth) · MAHNOB-HCI | MAE (bpm): 3.89 -> 3.01 | Improved |
| increase adaptation steps for proto-only variant from 10 to 30 (ablation) | Meta-rPPG (proto only) · MAHNOB-HCI | MAE (bpm): 6.05 -> 6.02 | No clear effect |
Closest papers by meaning
- Facial Video-based Remote Physiological Measurement via Self-supervised Learning (TPAMI 2023 · similarity 0.91)
- Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement (ECCV 2024 · similarity 0.90)
- FacePhys: State of the Heart Learning (NeurIPS 2026 · similarity 0.87)
- RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement (AAAI 2025 · similarity 0.87)
- Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios (CVPR 2025 · similarity 0.87)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
