AI Paper Atlas

Research map / 3D vision / Human pose estimation

"BodySLAM: Joint Camera Localisation, Mapping, and Human Motion Tracking"

Dorian F. Henning, Tristan Laidlow, Stefan Leutenegger

ECCV 2022 · 3D vision › Human pose estimation · approach: Physics and sensor-based motion capture · 23 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset (10 sequences)root trajectory error (H-ATE): 48.3% average improvementImproved
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset (10 sequences)joint trajectory error (J-ATE): 35.6% average improvementImproved
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset, seq E 1 (SE(3) alignment)C-ATE (mm): 108.1 -> 44.3Improved
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset (10 sequences)camera scale error: 0.35 to 0.74 -> 0.93 to 1.03Improved
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset seq M 3 (Sim(3) alignment)C-ATE (mm): 128 -> 128.1No clear effect
add the human motion model factor (ablation)monocular bundle adjustment baseline · BodySLAM dataset seq E 1 (Sim(3) alignment)H-ATE (mm): 106.5 -> 56.0Improved
add structural landmarks to the joint optimisation (ablation)BodySLAM · BodySLAM dataset (5 perturbed sequences)mean C-ATE (mm, SE(3)): 158.662 -> 155.572Improved
perturb camera scale by factor 5.0 before joint optimisation (ablation)BodySLAM · BodySLAM dataset scale recoveryscale deviation (%): 5.1 -> 26.5Hurt
perturb camera scale by factor 10 (1/s' = 0.1) before joint optimisation (ablation)BodySLAM · BodySLAM dataset scale recoveryscale deviation (%): 5.1 -> 24.0Hurt
use small scale perturbation (1/s' from 0.5 to 2.0) (ablation)BodySLAM · BodySLAM dataset scale recoveryscale deviation (%): 5.1 to 5.6No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy