What was changedWhereMeasuredEffect
add the extra loss terms beyond L_f (full loss) (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 62.65 -> 69.83Improved
use 2 3D conv layers in weighting network instead of none (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F1 (%): 48.57 -> 69.86Improved
increase 3D conv layers from 2 to 4 (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F1 (%): 69.86 -> 68.21No clear effect
add feature network (2D processing before unprojection) (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 67.44 -> 68.87Improved
add tanh normalization of weight counters (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 66.69 -> 68.92Improved
add feature grids to weights as weighting-network input (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 68.92 -> 69.83Improved
use 5 instead of 1 feature-network blocks (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 67.45 -> 68.39Mixed
vary feature dimension n from 2 to 5 (ablation)SenFuNet · Replica SGM+PSMNet ablation (no denoising)F-score (%): 68.86 -> 68.21No clear effect
add depth denoising network (ablation)SenFuNet · Replica ToF+PSMNet fusion (with denoising)F-score (%): 69.29 -> 76.47Improved
add depth denoising network (ablation)SenFuNet · Replica SGM+PSMNet fusion (with denoising)F-score (%): 69.83 -> 71.18Improved
late 3D fusion SenFuNet versus 2D Early Fusion with synchronized sensorsSenFuNet · Replica ToF+PSMNet fusion (with denoising)F-score (%): 74.60 -> 76.47Improved
lower ToF sampling rate from 1/2 to 1/3SenFuNet · Replica ToF+PSMNet time-asynchronous (ToF at 1/3 rate)F-score (%): Early Fusion 61.34 -> 55.52, SenFuNet 73.04 -> 74.93Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy