Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add monocular depth to the optical flow input (ablation) | CliffPhys Cl0,2 · COHFACE test | MAE (breaths/min): 0.90 -> 0.83 | Improved |
| add monocular depth to the optical flow input (ablation) | CliffPhys Cl3,0 · BP4D+ cross-dataset | MAE (breaths/min): 4.23 -> 3.50 | Improved |
| add depth to input for the simpler Cl2,0 algebra (ablation) | CliffPhys Cl2,0 · COHFACE test | MAE (breaths/min): 0.95 -> 1.06 | Hurt |
| use optical flow and depth input instead of raw RGB frames (ablation) | CliffPhys Cl3,0 · COHFACE test | MAE (breaths/min): 4.15 -> 0.99 | Improved |
| use Clifford layers instead of conventional 3D convolutional layers on the same flow and depth input (ablation) | CliffPhys · COHFACE test | MAE (breaths/min): 3.62 -> 0.83 | Improved |
| use 8-dimensional Clifford algebra (Cl3,0, Cl0,3) instead of 4-dimensional on cross-dataset (ablation) | CliffPhys · BP4D+ cross-dataset | MAE (breaths/min): Cl0,2 4.00 and Cl2,0 4.07 -> Cl3,0 3.50 | Improved |
| use CliffPhys instead of RGB-based neural baselines (MTTS-CAN, BigSmall, PhysFormer, ContrastPhys) | CliffPhys · COHFACE test | MAE (breaths/min): 2.83 (MTTS-CAN) -> 0.83 | Improved |
| compare CliffPhys Cl3,0 to ContrastPhys on cross-dataset MAE | CliffPhys · BP4D+ cross-dataset | MAE (breaths/min): 3.82 -> 3.50 | Improved |
Closest papers by meaning
- DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks (ECCV 2018 · similarity 0.82)
- FacePhys: State of the Heart Learning (NeurIPS 2026 · similarity 0.81)
- SCAMPS: Synthetics for Camera Measurement of Physiological Signals (NeurIPS 2022 · similarity 0.80)
- Fusion-Vital: Video-RF Fusion Transformer for Advanced Remote Physiological Measurement (AAAI 2024 · similarity 0.79)
- Towards Open Respiratory Acoustic Foundation Models: Pretraining and Benchmarking (NeurIPS 2024 · similarity 0.79)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.78)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.