Research map / Image generation / Autoregressive and latent generation
HERGen: Elevating Radiology Report Generation with Longitudinal Data
Fuying Wang, Shenghui Du, Lequan Yu
The University of Hong Kong
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add contrastive alignment between image sequences and reports (ablation) | HERGen · MIMIC-CXR | averaged NLG metrics: +3.3% | Improved |
| add contrastive alignment between image sequences and reports (ablation) | HERGen · Longitudinal MIMIC-CXR | averaged NLG metrics: +2.3% | Improved |
| add group causal transformer temporal aggregation (ablation) | HERGen · Longitudinal MIMIC-CXR | averaged NLG metrics: +4.9% | Improved |
| combine temporal aggregation with contrastive alignment (ablation) | HERGen · Longitudinal MIMIC-CXR | averaged NLG metrics: +4.9% -> +6.5% | Improved |
| add temporal aggregation and contrastive alignment on MIMIC-CXR (ablation) | HERGen · MIMIC-CXR | averaged NLG metrics: +5.9% | Improved |
| use longitudinal history across visits instead of single-image generation (CvT-212DistilGPT2) | report generation · Longitudinal MIMIC-CXR | CE F1: 0.261 -> 0.295 | Improved |
| use HERGen instead of CvT-212DistilGPT2 on MIMIC-CXR precision | report generation · MIMIC-CXR | CE precision: 0.417 -> 0.415 | No clear effect |
| use HERGen temporal pretraining instead of BioViL-T for temporal image classification | MS-CXR-T · MS-CXR-T | macro-accuracy (%): pneumonia 52.0 -> 66.7; edema 52.0 -> 48.1 | Mixed |
Later papers that compared with this method
1 later accepted paper reports HERGen as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.
- TIM: Temporal Decoupling with Iterative Mutual-Refinement Model for Longitudinal Radiology Report Generation (CVPR 2026 · better on 1 of 1 shared result)
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- TIM: Temporal Decoupling with Iterative Mutual-Refinement Model for Longitudinal Radiology Report Generation (CVPR 2026 · similarity 0.90)
- HC-LLM: Historical-Constrained Large Language Models for Radiology Report Generation (AAAI 2025 · similarity 0.90)
- Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation (CVPR 2025 · similarity 0.89)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.87)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.87)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
