What was changedWhereMeasuredEffect
add an auxiliary restoration branch guiding segmentation (ablation)MetaScope · Meta-CVC-ClinicmDICE: 0.8272 -> 0.8573Improved
add gradient-guided distillation from DINOv2 (instead of unguided distillation) (ablation)MetaScope · Meta-CVC-ClinicmDICE: 0.8750 -> 0.8927Improved
add Optics-informed Chromatic Correction (OCC) (ablation)MetaScope · Meta-CVC-ClinicPSNR: 32.8153 -> 34.0011Improved
use multi-expert Gaussian (MeG) in OCC (ablation)MetaScope OCC · Meta-CVC-ClinicPSNR: 32.8078 -> 34.0011Improved
add Optics-informed Intensity Adjustment (OIA) with optical prior (ablation)MetaScope · Meta-CVC-ClinicPSNR: 34.1341 -> 34.8483Improved
use simulated spatial plus channel optical priors instead of directly learned embedding (ablation)MetaScope OIA · Meta-EndoVis-17mIoU: 0.8700 -> 0.8802Improved
use 3 Gaussian experts instead of 1 (ablation)MetaScope OCC · Meta-EndoVis-17mIoU: 0.8682 -> 0.8802Improved
increase experts from 3 to 5 (ablation)MetaScope OCC · Meta-EndoVis-17mIoU: 0.8802 -> 0.8793No clear effect
raise restoration loss weight lambda from 0.1 to 1.0 (ablation)MetaScope · Meta-EndoVis-17mIoU: 0.8802 -> 0.8497Mixed
train one unified model on all five datasets versus DRMIMetaScope · Meta-CVC-Clinic restorationPSNR: 34.05 -> 36.47Improved
fine-tune on the new metalens (5 mm) after zero-shot transferMetaScope · Cross-metalens CVC-ClinicmIoU: 82.82 -> 86.37Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy