Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add high-quality contrastive learning (HqCL) to CPS baseline (ablation) | CPS · FLARE 2022 (10% labeled) | mean Dice: 79.32 -> 82.00 | Improved |
| add DVCL loss on unreliable voxels on top of HqCL (ablation) | CPS + HqCL · FLARE 2022 (10% labeled) | mean Dice: 82.00 -> 83.41 | Improved |
| add neighbor partitioning strategy (NPS) (ablation) | CPS + HqCL + DVCL · FLARE 2022 (10% labeled) | mean Dice: 83.41 -> 84.09 | Improved |
| add query detection strategy (QDS) to exclude outlier queries (ablation) | CPS + HqCL + DVCL + NPS · FLARE 2022 (10% labeled) | mean Dice: 84.09 -> 84.15 | No clear effect |
| add all components (HqCL, DVCL, NPS, QDS) to CPS baseline (ablation) | CPS · FLARE 2022 (10% labeled) | mean Jaccard: 68.14 -> 73.62 | Improved |
| use DVCL log-likelihood loss instead of InfoNCE (ablation) | DVCL · FLARE 2022 (10% labeled) | mean Dice: 83.05 -> 83.41 | Improved |
| use DVCL log-likelihood loss instead of SimCLR (ablation) | DVCL · FLARE 2022 (10% labeled) | mean Dice: 82.77 -> 83.41 | Improved |
| use DVCL log-likelihood loss instead of NNCLR (ablation) | DVCL · FLARE 2022 (10% labeled) | mean Dice: 83.17 -> 83.41 | Improved |
| add SNCLR cosine-similarity weighting to log-likelihood loss (ablation) | DVCL log-likelihood · FLARE 2022 (10% labeled) | mean Dice: 83.41 -> 83.69 | No clear effect |
| add NPS weighting to log-likelihood loss instead of SNCLR weighting (ablation) | DVCL log-likelihood · FLARE 2022 (10% labeled) | mean Dice: 83.69 -> 84.09 | Improved |
| fill unreliable voxels via DVCL instead of discarding them (UGPCL) or complementary-label push (U2PL) | semi-supervised multi-organ segmentation · FLARE 2022 (10% labeled) | mean Dice: 82.1 -> 84.2 | Improved |
| DVCL vs second-best method at 10% labels on AMOS | DVCL · AMOS (10% labeled) | mean Dice: 65.8 -> 71.4 | Improved |
Closest papers by meaning
- Rethinking Semi-Supervised Medical Image Segmentation: A Variance-Reduction Perspective (NeurIPS 2023 · similarity 0.89)
- Neighbor Does Matter: Density-Aware Contrastive Learning for Medical Semi-supervised Segmentation (AAAI 2025 · similarity 0.88)
- A Dual-space Patch-driven Complementary Learning Framework for Semi-supervised Multi-organ Segmentation (ECCV 2026 · similarity 0.88)
- DyCON: Dynamic Uncertainty-aware Consistency and Contrastive Learning for Semi-supervised Medical Image Segmentation (CVPR 2025 · similarity 0.86)
- A Semantic Knowledge Complementarity based Decoupling Framework for Semi-supervised Class-imbalanced Medical Image Segmentation (CVPR 2025 · similarity 0.85)
- DuSSS: Dual Semantic Similarity-Supervised Vision-Language Model for Semi-Supervised Medical Image Segmentation (AAAI 2025 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.