AI Paper Atlas

Research map / Label-efficient and robust learning / Self-supervised and contrastive

ASCENT: Annotation-free Self-supervised Contrastive Embeddings for 3D Neuron Tracking in Fluorescence Microscopy

Haejun Han, Hang Lu

ICCV 2025 · Label-efficient and robust learning › Self-supervised and contrastive · approach: Invariance-based self-supervised learning · 2 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace single MIP with iterative volume compression (ablation)VCE-Net · NeRVE (100 frames)plateau accuracy: 83.30 -> 95.04Improved
use volume compression instead of full 3D convolution (ablation)VCE-Net · NeRVE (100 frames)plateau accuracy: 57.80 -> 95.04Improved
add local patch pathway (ablation)VCE-Net · NeRVE (100 frames)plateau accuracy: 92.98 -> 95.04Improved
use ResNet-34 instead of ResNet-18 backbone (ablation)VCE-Net · NeRVE (100 frames)plateau accuracy: 95.04 -> 95.09No clear effect
use ResNet-50 instead of ResNet-18 backbone (ablation)VCE-Net · NeRVE (100 frames)plateau accuracy: 95.04 -> 95.02No clear effect
train on 200 instead of 100 regularly sampled frames (ablation)ASCENT · NeRVEplateau accuracy: 95.04% vs. 95.20%Improved
use uniformly sampled 100 frames instead of first 100 frames (ablation)ASCENT · NeRVEplateau accuracy: 94.44% vs. 95.04%Improved
train on only 12 frames (ablation)ASCENT · NeRVEplateau accuracy: around 93%Mixed
add data augmentations (all five transforms vs none) (ablation)ASCENT · NeRVE (50 frames)plateau accuracy: 44.5% -> 94.4%Improved
add position jitter augmentation (ablation)ASCENT · NeRVE (50 frames)plateau accuracy: -7.1% when omitted; +45.4% aloneImproved
add elastic deformation augmentation (ablation)ASCENT · NeRVE (50 frames)plateau accuracy: +0.1% when removedNo clear effect
train on NeRVE rather than in-house data, test on NeRVE (ablation)ASCENT · NeRVE testtracking accuracy after epoch 100: 71.73% -> 95.07%Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft