AI Paper Atlas

Research map / 3D vision / Depth and stereo

Optical Model-Driven Sharpness Mapping for Autofocus in Small Depth-of-Field and Severe Defocus Scenarios

Chen-Liang Fan, Mingpei Cao, Chih Chien Hung, Yuesheng Zhu

ICCV 2025 · 3D vision › Depth and stereo · approach: Depth from light field and defocus · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use U2-Net instead of U-Net for sharpness regression (ablation)sharpness network · 800 focal stacksMAE: 0.0582 -> 0.057Improved
use U2-Net instead of ViT for sharpness regression (ablation)sharpness network · 800 focal stacksMAE: 0.0639 -> 0.057Improved
use U2-Net instead of Res-Unet (ablation)sharpness network · 800 focal stacksMAE: 0.06 -> 0.057Improved
use U2-Net instead of Dense-Unet (ablation)sharpness network · 800 focal stacksMAE: 0.0607 -> 0.057Improved
replace direct distance estimation with optical-model sharpness plus adaptive adjustment (vs Herrmann et al., Anodized)autofocus pipeline · AOI Anodized, 5 iterationsin-focus rate: 0.455 -> 0.998Improved
replace depth-from-defocus model (Nazir et al.) with sharpness mapping, Paper textureautofocus pipeline · AOI Paper, 5 iterationsin-focus rate: 0.759 -> 0.947Improved
replace coarse-to-fine peak search with sharpness mapping (Modified DCT best conventional)autofocus pipeline · AOI severe defocusin-focus rate: 0.93 (10 steps) -> 0.912 (3 steps)Improved
wrong initial direction (take one more step to resolve ambiguity)Ours · AOI severe defocusin-focus rate: 0.912 (3 steps) vs 0.962 (5 steps)Mixed
bright illumination instead of normalOurs · metal samples, step 3in-focus rate: 0.958 -> 0.754Hurt
dark illumination instead of normalOurs · metal samples, step 3in-focus rate: 0.958 -> 0.923No clear effect
printed paper texture instead of anodizedOurs · step 3in-focus rate: 0.996 -> 0.719Hurt
severe defocus start vs all-range startOurs · step 5, initial direction correctin-focus rate: 0.967 -> 0.975No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy