AI Paper Atlas

Research map / 3D vision / Face and shape

Joint Embedding of 3D Scan and CAD Objects

Manuel Dahnert, Angela Dai, Leonidas J. Guibas, Matthias Niessner

ICCV 2019 · 3D vision › Face and shape · approach: Primitive-based shape abstraction · 36 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add scan segmentation hourglass (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (class avg): 0.19 -> 0.39Improved
add scan completion hourglass (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (class avg): 0.16 -> 0.39Improved
add segmentation and completion together (ablation)joint scan-CAD embedding · Scan-CAD embedding confusion (class avg)confusion (class avg): 0.16 -> 0.50Improved
add segmentation (ablation)joint scan-CAD embedding · Scan-CAD embedding confusion (class avg)confusion (class avg): 0.49 -> 0.50No clear effect
add completion (ablation)joint scan-CAD embedding · Scan-CAD embedding confusion (class avg)confusion (class avg): 0.24 -> 0.50Improved
train with negative samples (triplet loss) instead of positives only (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (class avg): 0.10 -> 0.39Improved
add triplet negatives (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (ranking quality, inst avg)ranking quality (inst avg): 0.04 -> 0.16Improved
train end-to-end (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (class avg): 0.29 -> 0.39Improved
use own completion network instead of 3D-EPN (ablation)joint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (class avg): 0.30 -> 0.39Improved
use own segmentation instead of SGPNscan segmentation · Scan segmentation/completion IoUIoU: 0.10 -> 0.36Improved
use own completion instead of 3D-EPN after segmentationscan completion · Scan segmentation/completion IoUIoU: 0.48 -> 0.53Improved
train with rotation augmentation and test on random rotationsjoint scan-CAD embedding · Scan-CAD Object Similarity test (retrieval accuracy, inst avg)top-1 retrieval accuracy (inst avg): 0.43 -> 0.42No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy