AI Paper Atlas

Research map / 3D vision / Depth and stereo

QUARCH: A New Quasi-Affine Reconstruction Stratum From Vague Relative Camera Orientation Knowledge

Devesh Adlakha, Adlane Habed, Fabio Morbidi, Cedric Demonceaux, Michel de Mathelin

ICCV 2019 · 3D vision › Depth and stereo · approach: Camera model and calibration for SfM · 2 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use QUARCH plane initialisation instead of QUARC with unconstrained minimisation (ablation)metric upgrade from projective reconstruction · synthetic, 4-5 viewssuccess rate / median 3D errorImproved
use QUARCH plane instead of QUARC with Nister cost function (ablation)metric upgrade · syntheticmetric upgrade reliabilityImproved
add QUARCH LMI constrained optimisation to QUARCH-M (ablation)QUARCH-M · syntheticmetric upgrade successImproved
use constrained QUARCH*M instead of unconstrained QUARCH-M in runtime (ablation)QUARCH · synthetic, up to 16 viewsruntime: < 1.2s up to 16 viewsHurt
use QUARCH*M instead of GO-Stratifiedself-calibration · synthetic, 4-5 viewsmedian 3D error and success rateImproved
use QUARCH*M instead of QUARC-M on Herz-Jesu-P8 (ablation)self-calibration · Herz-Jesu-P8focal length error (pixels): 4114.66 -> 53.49Improved
use QUARCH*M instead of GO-Stratified on Herz-Jesu-P8self-calibration · Herz-Jesu-P8focal length error (pixels): 2552.62 -> 53.49Improved
use QUARCH*M instead of QUARC-M on fountain-P11 (ablation)self-calibration · fountain-P11focal length error (pixels): 2.44 -> 1.91Improved
use QUARCH*M instead of QUARC-M on Herz-Jesu-P25 (ablation)self-calibration · Herz-Jesu-P25focal length error (pixels): 34.75 -> 34.89No clear effect
use QUARCH*M instead of QUARC-M in runtime on fountain-P11 (ablation)self-calibration · fountain-P11runtime (s): 0.09 -> 2.71Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy