AI Paper Atlas

Research map / 3D vision / Depth and stereo

Volumetric Flow Estimation for Incompressible Fluids Using the Stationary Stokes Equations

Katrin Lasinger, Christoph Vogel, Konrad Schindler

ICCV 2017 · 3D vision › Depth and stereo · approach: Learned optical and scene flow · 14 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add hard divergence-free constraint to quadratic regularization (QR to QRD∞) (ablation)3D variational flow with SSD · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.408 -> 0.369Improved
use quadratic regularization instead of TV (ablation)3D variational flow with SSD · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.462 -> 0.408Improved
replace soft divergence penalty with hard constraint (ablation)QRD · JHTDB PIV volume 1024x512x352AEE: 0.371 -> 0.369No clear effect
increase soft divergence penalty alpha from 0 to 64 (ablation)QRDα · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.408 -> 0.371Improved
increase soft penalty alpha from 64 to 128 (ablation)QRDα · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.371 -> 0.375Hurt
enlarge interrogation volume from 7^3 to 11^3 (ablation)SSD+QRD∞ · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.406 -> 0.369Improved
enlarge interrogation volume beyond 11^3 (13^3, 15^3) (ablation)SSD+QRD∞ · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.369 -> 0.364No clear effect
lower particle density from 0.1 to 0.075 ppp (ablation)SSD+QRD∞ · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.369 -> 0.340Improved
raise particle density from 0.1 to 0.15 ppp (ablation)SSD+QRD∞ · JHTDB PIV volume 1024x512x352 (MART reconstruction)AEE: 0.369 -> 0.571Hurt
compute flow on coarser grid h=2 instead of full resolution h=1 (ablation)SSD+QRD∞ · JHTDB PIV volume 256x256x256 (MART reconstruction)AEE: 0.347 -> 0.342Improved
coarsen flow grid spacing from h=2 to h=6 (ablation)SSD+QRD∞ · JHTDB PIV volume 256x256x256 (MART reconstruction)AEE: 0.342 -> 0.468Hurt
use noise-free particle volume instead of MART reconstruction (ablation)SSD+QRD∞ · JHTDB PIV volume 1024x512x352, 0.1 pppAEE: 0.369 -> 0.227Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy