AI Paper Atlas

Research map / 3D vision / Depth and stereo

Using Sparse Elimination for Solving Minimal Problems in Computer Vision

Janne Heikkila

ICCV 2017 · 3D vision › Depth and stereo · approach: Camera model and calibration for SfM · 11 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use sparse elimination basis selection instead of modified resultant basisPEP solver for equal-focal-length self-calibration · Synthetic, sigma=0.5 pxmean relative error: 0.1947 -> 0.1935Improved
use sparse elimination basis selection instead of modified resultant basisPEP solver for equal-focal-length self-calibration · Noise-free synthetic datarelative error distributionImproved
use sparse elimination basis selection instead of modified resultant basisPEP solver for equal-focal-length self-calibration · Real images (checkerboard, 3 images, 27 of 54 points)relative errorImproved
use sparse elimination basis selection instead of modified resultant basisPEP solver for equal-focal-length self-calibration · Real images (transparency film box, 14 images)relative errorImproved
use sparse elimination instead of modified resultant basisPEP solver · Equal focal length problemspurious roots: 99 -> 12Improved
use sparse elimination instead of modified resultant basisPEP solver · Equal focal length problemexecution time (ms): 17.5 -> 3.2Improved
rescale pixel values by 1/10 before computing homographies (ablation)SPE solver · Synthetic noise sigma=0.5 pxnumerical stabilityImproved
use more points than the minimum four for homography estimation (ablation)SPE solver · Real checkerboard imagesrelative error: 4 points (minimum) vs 27 pointsImproved
remove zero monomials via SVD-based elimination (ablation)MRE with random equation selection · Equal focal length problemstability: removed 11 zero monomialsImproved
use unequal focal length problem (4 constraints instead of 3) in noisy dataSPE2 · Synthetic sigma=0.5 pxprecisionImproved
use unequal focal length problem in noise-free dataSPE2 · Noise-free synthetic dataprecisionHurt
removing 15 common zero columns from C0 and C1 (ablation)SPE2 (basis 191) · Unequal focal length problemnumber of solutions: 191 -> 176Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy