atlas

Research map / Detection and segmentation / Weakly supervised detection and segmentation

MonoBox: Tightness-Free Box-Supervised Polyp Segmentation Using Monotonicity Constraint

AAAI 2025 · Detection and segmentation › Weakly supervised detection and segmentation · approach: Weakly supervised semantic segmentation · 9 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes MonoBox, a tightness-free box-supervised polyp segmentation method that replaces MIL loss in noisy box-edge zones with a monotonicity constraint and shrinks those zones via label correction.

Problem

Box-supervised polyp segmentation relies on the box-tightness assumption (box edges touch target boundaries), which fails for polyps with vague boundaries, producing noisy MIL supervision.

Approach

Within unconfident zones near box edges, discard MIL loss and enforce a monotonicity constraint (inner response higher than outer response along directions toward the box center), plus adaptive label correction using predicted-mask boxes that shrinks the unconfident zones during training.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
apply MonoBox instead of FSRMWeakPolyp · Real noisyDice: 0.785 -> 0.804Helped
apply MonoBox instead of FSRMWeakPolyp · Synthetic noisyDice: 0.722 -> 0.763Helped
apply MonoBox instead of FSRMIBoxCLA · Real noisyDice: 0.816 -> 0.849Helped
apply MonoBox instead of FSRMIBoxCLA · Synthetic noisyDice: 0.748 -> 0.803Helped
add monotonicity constraint (ablation)IBoxCLA box-supervised segmentation · Real noisyDice: 0.803 -> 0.838Helped
add monotonicity constraint (ablation)IBoxCLA box-supervised segmentation · Synthetic noisyDice: 0.735 -> 0.787Helped
add label correction without MC (ablation)IBoxCLA box-supervised segmentation · Real noisyDice: 0.803 -> 0.809Helped
add label correction without MC (ablation)IBoxCLA box-supervised segmentation · Synthetic noisyDice: 0.735 -> 0.744Helped
combine monotonicity constraint and label correction (ablation)IBoxCLA box-supervised segmentation · Real noisyDice: 0.838 -> 0.849Helped
combine monotonicity constraint and label correction (ablation)IBoxCLA box-supervised segmentation · Synthetic noisyDice: 0.787 -> 0.803Helped
exclude the unconfident region from loss calculation instead of using MC (ablation)IBoxCLA box-supervised segmentation · Real noisyDice: 0.803 -> 0.809No clear effect
use 2D-Gaussian soft labels instead of MC (ablation)IBoxCLA box-supervised segmentation · Real noisyDice: 0.803 -> 0.816Helped

Surprising findings

Limitations

Experimental setup

Datasets: ClinicDB Kvasir-SEG ColonDB EndoScene ETIS in-house polyp dataset COCO

Benchmarks: ClinicDB Kvasir-SEG ColonDB EndoScene ETIS in-house real noisy polyp test set COCO test-dev

Metrics: Dice IoU Hausdorff distance AP

Baselines: SSD-Det NCE+RCE PolarT FSRM Soft Label (2D-Gaussian) Exclusion BoxInst WeakPolyp IBoxCLA

Builds on: multiple-instance learning BoxInst IBoxCLA FSRM

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy