AI Paper Atlas

Research map / Architectures and efficiency / RNNs and normalization

D2T2 - Multimodal Automated Planning for Brachytherapy

Lance C. Moore, Aranyo Mitra, Ryan Truong, Karoline Kallis, Kelly Kisling, Sandra M. Meyers, Nuno Vasconcelos

CVPR 2026 · Architectures and efficiency › RNNs and normalization · approach: Differentiable optimization layers

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace post-hoc dose optimization with a physics layer predicting dwell times end-to-end (D2T2)brachytherapy dose prediction · Brachytherapy test set (overall)Dose MAE (%): 4.41 -> 3.54Improved
replace post-hoc dose optimization with a physics layer predicting dwell times end-to-end (D2T2)brachytherapy dose prediction · Brachytherapy test set (overall)Dwell time MAE (s): 11.79 -> 7.41Improved
replace post-hoc dose optimization with a physics layer predicting dwell times end-to-end (D2T2)brachytherapy dose prediction · Brachytherapy test set (overall)Mean time (s): 35.07 -> 0.10Improved
use D2T2 instead of OPT on low-data Other sitesD2T2 · Other-site plansDose MAE (%): 5.09 -> 3.75Improved
use D2T2 instead of OPT on vaginal plansD2T2 · Vaginal plansDose MAE (%): 6.55 -> 6.51No clear effect
train with gamma loss instead of dose L2 loss (ablation)D2T2 · Brachytherapy test set (loss ablation)Dose MAE (%): 3.68 -> 3.64Improved
add dwell time L2 loss to the dose loss (ablation)D2T2 · Brachytherapy test set (loss ablation)Dose MAE (%): 3.68 -> 4.67Hurt
add dwell time L2 loss to the dose loss (ablation)D2T2 · Brachytherapy test set (loss ablation)Dwell time MAE (s): 7.41 -> 7.49No clear effect
train on dwell time L2 loss alone (ablation)D2T2 · Brachytherapy test set (loss ablation)Dose MAE (%): 3.68 -> 4.34Hurt
add gamma loss to dose loss without weighting (ablation)D2T2 · Brachytherapy test set (loss ablation)Dwell time MAE (s): 7.41 -> 7.85Hurt
weight gamma loss with lambda 0.05 in the combined loss (ablation)D2T2 · Brachytherapy test set (lambda ablation)Dose MAE (%): 3.69 -> 3.54Improved
weight gamma loss with lambda 0.05 in the combined loss (ablation)D2T2 · Brachytherapy test set (lambda ablation)Dwell time MAE (s): 7.85 -> 7.41Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy