What was changedWhereMeasuredEffect
add dynamic test-time temperature calibration (ablation)FRAP (CLIP) · Average over 18 datasetsMAE (%): 8.20 -> 6.53Improved
use learned test-time temperature instead of fixed 0.05 (ablation)FRAP (CLIP) · Average over 18 datasetsMAE (%): 8.19 -> 6.53Improved
use learned test-time temperature instead of fixed 0.01 (ablation)FRAP (CLIP) · Average over 18 datasetsMAE (%): 6.61 -> 6.53Improved
use test-time calibration instead of raw CLIP similarity (ablation)FRAP (CLIP) · CIFAR-10ECE: 0.590 -> 0.128Improved
use test-time calibration instead of raw CLIP similarity (ablation)FRAP (CLIP) · MNISTECE: 0.027 -> 0.073Hurt
use fixed tau=0.01 instead of test-time calibration (ablation)FRAP (CLIP) · Several datasetsECEMixed
add confidence-weighted fusion of foundation and base predictions (ablation)FRAP · ImageNet natural shiftDelta SAS vs base model: improvement in 100.0% of experiments, mean 0.249Improved
add confidence-weighted fusion over CLIP alone (ablation)FRAP · ImageNet natural shiftDelta SAS vs CLIP: improvement 98.6%, mean 0.486Improved
add confidence-weighted fusion under synthetic corruption (ablation)FRAP · ImageNet synthetic shiftDelta SAS vs base model: improvement 64.4%, mean 0.102Improved
use FRAP fusion instead of CLIP pseudo-labels as ground truth (ablation)FRAP (CLIP) · Average over 18 datasetsMAE (%): 10.32 -> 6.53Improved
use FRAP fusion instead of SigLIP pseudo-labels as ground truth (ablation)FRAP (SigLIP) · Average over 18 datasetsMAE (%): 9.21 -> 7.32Improved
use fixed-temperature calibration instead of TTC with SigLIP (ablation)FRAP (SigLIP) · Average over 18 datasetsMAE (%): 7.32 -> 5.65Hurt