Measured effects reported in the paper

What was changedWhereMeasuredEffect
filter 10% highest-AUV samples using MedSAM2 featuresnnU-Net · LiTSDice (%): 82.96 -> 85.45Improved
use MedSAM2 instead of task-specific nnU-Net as feature extractor for AUV (ablation)AUV data filtering · Five datasets meanMean Dice (%): 75.17 -> 76.45Improved
use CLIP-Driven as feature extractor (ablation)AUV data filtering · Five datasets meanMean Dice (%): 75.03No clear effect
filter using data variance instead of foundation-model AUV (ablation)nnU-Net · Five datasets meanMean Dice (%): 75.10 -> 75.39No clear effect
add DUO to nnU-NetnnU-Net · Five datasets meanMean Dice (%): 75.10 -> 75.69Improved
add DUO to Swin-UNETRSwin-UNETR · Five datasets meanMean Dice (%): 73.09 -> 73.64Improved
add DUO to U-MambaU-Mamba · Five datasets meanMean Dice (%): 74.13 -> 74.66Improved
add re-weighting (RW) by semantic perception scale (ablation)DUO · LiTS tumorTumor Dice (%): 69.87 -> 71.66Improved
add estimated noise (EN) label denoising (ablation)DUO · LiTS tumorTumor Dice (%): 71.37 -> 71.66Improved
use singular value energy S instead of Fisher/MD/EAOA (ablation)AUV data filtering · LiTS tumor, 90% dataTumor Dice (%): 70.41 -> 74.28Improved
normalize input with foreground mask (strategy c) instead of raw image (a) (ablation)AUV data filtering · LiTS tumor, 90% dataTumor Dice (%): 73.35 -> 74.28Improved
filter 5% instead of 10% of samples (ablation)AUV data filtering · LiTS tumorTumor Dice (%): 74.28 -> 70.03Hurt