Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| filter 10% highest-AUV samples using MedSAM2 features | nnU-Net · LiTS | Dice (%): 82.96 -> 85.45 | Improved |
| use MedSAM2 instead of task-specific nnU-Net as feature extractor for AUV (ablation) | AUV data filtering · Five datasets mean | Mean Dice (%): 75.17 -> 76.45 | Improved |
| use CLIP-Driven as feature extractor (ablation) | AUV data filtering · Five datasets mean | Mean Dice (%): 75.03 | No clear effect |
| filter using data variance instead of foundation-model AUV (ablation) | nnU-Net · Five datasets mean | Mean Dice (%): 75.10 -> 75.39 | No clear effect |
| add DUO to nnU-Net | nnU-Net · Five datasets mean | Mean Dice (%): 75.10 -> 75.69 | Improved |
| add DUO to Swin-UNETR | Swin-UNETR · Five datasets mean | Mean Dice (%): 73.09 -> 73.64 | Improved |
| add DUO to U-Mamba | U-Mamba · Five datasets mean | Mean Dice (%): 74.13 -> 74.66 | Improved |
| add re-weighting (RW) by semantic perception scale (ablation) | DUO · LiTS tumor | Tumor Dice (%): 69.87 -> 71.66 | Improved |
| add estimated noise (EN) label denoising (ablation) | DUO · LiTS tumor | Tumor Dice (%): 71.37 -> 71.66 | Improved |
| use singular value energy S instead of Fisher/MD/EAOA (ablation) | AUV data filtering · LiTS tumor, 90% data | Tumor Dice (%): 70.41 -> 74.28 | Improved |
| normalize input with foreground mask (strategy c) instead of raw image (a) (ablation) | AUV data filtering · LiTS tumor, 90% data | Tumor Dice (%): 73.35 -> 74.28 | Improved |
| filter 5% instead of 10% of samples (ablation) | AUV data filtering · LiTS tumor | Tumor Dice (%): 74.28 -> 70.03 | Hurt |
Closest papers by meaning
- DyCON: Dynamic Uncertainty-aware Consistency and Contrastive Learning for Semi-supervised Medical Image Segmentation (CVPR 2025 · similarity 0.88)
- Multi-view Evidential Learning-based Medical Image Segmentation (AAAI 2025 · similarity 0.88)
- S2S2: Semantic Stacking for Robust Semantic Segmentation in Medical Imaging (AAAI 2025 · similarity 0.87)
- ConDSeg: A General Medical Image Segmentation Framework via Contrast-Driven Feature Enhancement (AAAI 2025 · similarity 0.87)
- Training Like a Medical Resident: Context-Prior Learning Toward Universal Medical Image Segmentation (CVPR 2024 · similarity 0.86)
- ValUES: A Framework for Systematic Validation of Uncertainty Estimation in Semantic Segmentation (ICLR 2024 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.