Research map / Probabilistic and scientific modeling / Molecules and proteins
Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation
Read the paperCheck your idea against 108,967 papers
AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Proposes cylindrical geodesic flow matching, which learns paired PPG and SCG waveform translation on the phase-amplitude cylinder using a closed-form geodesic bridge instead of the affine path.
Problem
Paired translation between quasiperiodic physiological waveforms (e.g., sternum-to-finger PPG, clavicle-to-sternum SCG) where phase is circular, amplitude is positive, and beat alignment drifts; standard affine flow-matching paths distort amplitude and instantaneous frequency.
Approach
Embed each analytic-signal sample as (cos phi, sin phi, a) on the phase-amplitude cylinder and use the closed-form shortest-arc geodesic as the conditional flow matching bridge, with an oracle velocity of constant norm and an intrinsic tangent parameterization with per-substep projection.
Key results
- On PPG under HT, cylindrical geodesic path gives HT Dist 0.8294, L2 0.5944, DTW 4.7902, best on all metrics versus time-series affine (0.9073, 0.6951, 5.6048).
- On SCG under HT, cylindrical geodesic path achieves HT Dist 0.8936, L2 0.6181, DTW 4.2618, best on all three metrics versus direct supervised (1.0419, 0.7103, 4.9158).
- Reductions of roughly 9-15% over the strongest competing baseline in the best cells; under EHT on PPG, direct supervision is marginally better on HT Dist (0.9777 vs 1.0110).
Surprising findings
- The Hilbert naive path trained in the same (phi, a) coordinates without cylindrical embedding is worse than the source reference on SCG, indicating naive phase-amplitude training fails.
- Under EHT on PPG, direct supervised prediction is best on HT Dist, so the geodesic advantage is not uniform across metrics and transforms.
Limitations
- Uses flat product metric d phi^2 + da^2; log-amplitude or Fisher-Rao metrics not explored.
- Analytic-signal representation is ill-defined near low-amplitude segments, where EHT only partially mitigates.
- Evaluated only on two cardiovascular translation tasks from a single institution; no cross-site or sensor heterogeneity tests.
Experimental setup
Datasets: in-house PPG cohort (20 subjects) in-house SCG cohort (13 subjects, 24 sessions)
Benchmarks: in-house PPG zero-shot translation in-house SCG limited-support adaptation
Metrics: HT Dist L2 error DTW distance
Baselines: Hilbert naive path time series affine path direct supervised predictor
Builds on: conditional flow matching Riemannian flow matching Hilbert transform extended Hilbert transform
Closest papers by meaning
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.83)
- Bidirectional Recurrence for Cardiac Motion Tracking with Gaussian Process Latent Coding (NeurIPS 2024 · similarity 0.83)
- Region-Disentangled Diffusion Model for High-Fidelity PPG-to-ECG Translation (AAAI 2024 · similarity 0.83)
- Constraint Latent Space Matters: An Anti-anomalous Waveform Transformation Solution from Photoplethysmography to Arterial Blood Pressure (AAAI 2024 · similarity 0.83)
- Riemannian Flow Matching for Brain Connectivity Matrices via Pullback Geometry (NeurIPS 2025 · similarity 0.83)
- B[FM]$^2$: Brain Foundation Model via Flow Matching with SplitUNet (NeurIPS 2026 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
