AI Paper Atlas

Research map / Learning theory and algorithms / Matrix and tensor methods

Can Metadata Fix the Gauge? Calibration Turns Sparse Multi-Source Learning from Sparse PCA into Sparse Mean Recovery

Yibo Zhou, Yirong Xiang

NeurIPS 2026 · Learning theory and algorithms › Matrix and tensor methods · approach: Sparse regression with guarantees · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Shows that source-specific sign gauges make pooled multi-source sparse learning reduce to sparse PCA, and that task-independent relative-gauge metadata lets synchronization restore a sparse mean-recovery problem.

Problem

Sparse Gaussian multi-source learning where each source orients its coordinates with an unknown sign gauge; without calibration, pooling erases the mean signal and the problem becomes sparse PCA.

Approach

Uses task-independent relative-gauge metadata with synchronization to align source-specific sign gauges, turning the problem from sparse PCA into sparse mean recovery.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Add valid relative-gauge calibration (synchronization) before poolingSparse multi-source recovery · Digits (imposed gauges)accuracy: 0.500 -> 0.968Improved
Add valid relative-gauge calibration (synchronization) before poolingSparse multi-source recovery · Breast cancer (imposed gauges)accuracy: 0.501 -> 0.932Improved
Use random metadata instead of valid calibration (ablation)Sparse multi-source recovery · Digitsaccuracy: 0.500 -> 0.525No clear effect
Use shuffled metadata instead of valid calibration (ablation)Sparse multi-source recovery · Breast canceraccuracy: 0.501 -> 0.557No clear effect
Use noisy absolute calibration with 10% flips instead of relative synchronization (ablation)Sparse multi-source recovery · Digitsaccuracy: 0.968 -> 0.874Hurt
Use source-label task alignment (uses downstream labels) instead of calibration (ablation)Sparse multi-source recovery · Digitsaccuracy: 0.968 -> 0.818Hurt
Reuse one synchronized calibration graph across 32 tasksGSL · Reuse experimentCorr: 0.928 -> 0.928No clear effect
Increase aligned source count at fixed aligned mass from 1 to 32 (ablation)Calibrated recovery · Synthetic, M_q=4096Corr: 0.632 -> 0.917Improved
Increase aligned source count from 32 to 128 (ablation)Calibrated recovery · Synthetic, M_q=4096Corr: 0.917 -> 0.916No clear effect
Use source-label PCA instead of calibration (ablation)Sparse multi-source recovery · Reuse experimentCorr: 0.928 -> 0.040Hurt

Surprising findings

Experimental setup

Builds on: sparse PCA

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy