Measured effects reported in the paper

What was changedWhereMeasuredEffect
enforce graph balance with signed edges (vs positive graph) (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (LOSO)accuracy (%): 84.30 -> 93.68Improved
enforce graph balance (vs unbalanced signed graph) (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (LOSO)accuracy (%): 78.87 -> 93.68Improved
add contrastive term to MSE denoiser loss (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 81.44 -> 97.57Improved
add contrastive term to MSE denoiser loss (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)recall / specificity: recall 97.67 -> 95.98; specificity 99.32 -> 97.45Hurt
use Mahalanobis instead of Euclidean feature distance (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 96.80 -> 97.57 (convergence 1h55 -> 2h14)Improved
increase temporal sequence length beyond 10 (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 97.57 (10) -> 88.10 (100)Hurt
increase CNN blocks from 1 to 6 (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 65.15 -> 97.57Improved
increase CNN blocks beyond 6 (ablation)unrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 97.57 -> 97.44 (9), 97.42 (12)No clear effect
use the small unrolled model instead of large STFT + CNNunrolled graph denoiser · Turkish Epilepsy EEG (default split)accuracy (%): 97.57 vs 99.20 with 14,787 vs 11,533,928 paramsMixed