Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add BP calibration (T=1) to GrAPE (ablation) | GrAPE on AlexNet · CIFAR-100 | accuracy: 45.45 -> 62.63 | Improved |
| add BP calibration (T=1) to GrAPE (ablation) | GrAPE on VGG-16 · CIFAR-100 | accuracy: 32.40 -> 56.93 | Improved |
| add BP calibration (T=1) to DFA (ablation) | DFA on VGG-16 · CIFAR-100 | accuracy: 1.00 -> 29.40 | Improved |
| add BP calibration (T=1) to DFA (ablation) | DFA on AlexNet · CIFAR-100 | accuracy: 42.59 -> 49.37 | Improved |
| replace DFA fixed feedback with GrAPE learned aligned feedback | DFA on AlexNet · CIFAR-100 | accuracy: 42.59 -> 45.45 | Improved |
| replace DFA fixed feedback with GrAPE learned aligned feedback | DFA with T=1 calibration on VGG-16 · CIFAR-100 | accuracy: 29.40 -> 56.93 | Improved |
| use GrAPE instead of DFA, no calibration | DFA on ResNet-20 · CIFAR-100 | accuracy: 20.94 -> 24.28 | Improved |
| add BP calibration (T=1) to GrAPE (ablation) | GrAPE on ResNet-20 · CIFAR-100 | accuracy: 24.28 -> 64.82 | Improved |
| increase calibration interval from T=1 to T=50 (ablation) | GrAPE + calibration on ResNet-20 · CIFAR-100 | accuracy: 64.82 -> 36.79 | Hurt |
| add BP calibration (T=1) to GrAPE (ablation) | GrAPE on Transformer-Base macro · WikiText-103 | validation perplexity: 42.3 -> 33.1 | Improved |
| add BP calibration (T=1) to GrAPE (ablation) | GrAPE on Transformer-Base micro · WikiText-103 | validation perplexity: 81.1 -> 67.3 | Improved |
| increase calibration interval from T=1 to T=10 (ablation) | GrAPE + calibration on Transformer-Base micro · WikiText-103 | validation perplexity: 67.3 -> 78.2 | Hurt |
Closest papers by meaning
- Overcoming Rank Collapse in Feedback Alignment (NeurIPS 2026 · similarity 0.88)
- One-Time Soft Alignment Enables Resilient Learning without Weight Transport (NeurIPS 2026 · similarity 0.87)
- Forward Learning with Top-Down Feedback: Empirical and Analytical Characterization (ICLR 2024 · similarity 0.85)
- Implicit Regularization in Feedback Alignment Learning Mechanisms for Neural Networks (ICML 2024 · similarity 0.85)
- Revisiting Residual Connections: Orthogonal Updates for Stable and Efficient Deep Networks (NeurIPS 2025 · similarity 0.83)
- DFA-GNN: Forward Learning of Graph Neural Networks by Direct Feedback Alignment (NeurIPS 2024 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.