What was changedWhereMeasuredEffect
use Poisson-noise measurements instead of noise-free onesDDS · Medical CT (config i vs ii)PSNR (dB): 31.43 -> 20.12Hurt
use Poisson-noise measurements instead of noise-free onesDDS · Industrial CT (config i vs ii)PSNR (dB): 22.87 -> 18.23Hurt
replace Poisson noise with matched-level Gaussian noise (ablation)DDS · Noise-model comparisonreconstruction qualityImproved
increase DC step size eta moderately (ablation)DPS · CT reconstructionPSNR and data fitImproved
increase DC step size eta too far (ablation)DPS · CT reconstructionPSNRHurt
add explicit data-consistency optimization steps to latent diffusion (ReSample vs gradient-only PSLD) (ablation)Latent diffusion · Medical CT noise-free (40 angles)reconstruction coherenceImproved
add explicit data-consistency optimization steps to latent diffusion under noise (ablation)ReSample · Medical CT noisy (80 angles)image qualityHurt
use supervised training (SwinIR) instead of diffusion priorsDiffusion methods · Medical CT config ivPSNR (dB): 29.70 -> 30.79Improved
use diffusion priors instead of classical FBP/SIRTClassical reconstruction · Medical CT config ivPSNR (dB): 25.86 -> 29.70Improved
use pixel-space instead of latent-space diffusionDiffusion methods · CT reconstruction efficiencytime and memoryImproved
use diffusion priors under sparse/high-noise measurementsClassical and MBIR methods · Medical and industrial CTPSNRImproved
apply empirical linear value-range mapping to raw projectionsMCG · Medical CT raw projectionsPSNR (dB): 19.48 -> 29.12Improved