atlas

Research map / Vision-language and multimodal / Multimodal LLMs

Counterfactual Debiasing for Physical Audiovisual Commonsense Reasoning

AAAI 2025 · Vision-language and multimodal › Multimodal LLMs · approach: Chain-of-thought multimodal reasoning · 0 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes CF-PACR, a model-agnostic counterfactual debiasing framework that subtracts the natural direct effect of visual-only predictions from audiovisual total effects to reduce visual bias in physical audiovisual commonsense reasoning.

Problem

Physical audiovisual commonsense reasoning (PACR) models over-rely on visual features, learning spurious correlations from imbalanced object-material combinations in the PACS training data, which hurts generalization on rare combinations.

Approach

Use causal-graph counterfactual inference: estimate the natural direct effect of the visual pathway with a counterfactual model (learnable dummy vector for the no-treatment condition, trained with KL alignment) and subtract it from the total effect to obtain the total indirect effect used for prediction.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Apply CF-PACR to AudioCLIPAudioCLIP · PACS-QAaccuracy: 60.0±0.9 -> 63.6±0.8Helped
Apply CF-PACR to AudioCLIPAudioCLIP · PACS-Materialaccuracy: 66.2±1.0 -> 69.4±0.9Helped
Apply CF-PACR to MER-Res (L)MER-Res (L) · PACS-QAaccuracy: 70.1±0.7 -> 72.8±1.1Helped
Apply CF-PACR to MER-Res (L)MER-Res (L) · PACS-Materialaccuracy: 74.2±0.9 -> 76.5±1.0Helped
Apply CF-PACR to MER-Res (B)MER-Res (B) · PACS-QAaccuracy: 66.5±1.4 -> 68.7±0.8Helped
Apply CF-PACR to MER-Res (B)MER-Res (B) · PACS-Materialaccuracy: 72.2±1.2 -> 74.7±0.9Helped
Add counterfactual debiasing with SUM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-QAaccuracy: 60.7±0.8 -> 61.9±0.8Helped
Add counterfactual debiasing with SUM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-Materialaccuracy: 66.6±1.1 -> 67.5±0.9Helped
Add counterfactual debiasing with HM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-QAaccuracy: 60.9±0.7 -> 62.8±0.9Helped
Add counterfactual debiasing with HM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-Materialaccuracy: 66.8±0.9 -> 68.7±1.1Helped
Add counterfactual debiasing with LogSUM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-QAaccuracy: 61.4±1.1 -> 63.6±0.8Helped
Add counterfactual debiasing with LogSUM fusion (ablation)CF-PACR with CLIP and AudioCLIP · PACS-Materialaccuracy: 67.1±1.0 -> 69.4±0.9Helped

Surprising findings

Limitations

Experimental setup

Datasets: PACS

Benchmarks: PACS-QA PACS-Material

Metrics: accuracy

Baselines: CLIP UNITER (L) MERLOT AudioCLIP MERLOT Reserve (B) MERLOT Reserve (L) Late Fusion

Builds on: AudioCLIP MERLOT Reserve CLIP

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy