atlas

Research map / Architectures and efficiency / Pruning and efficient tuning

pMoE: Prompting Diverse Experts Together Wins More in Visual Adaptation

ICLR 2025 · Architectures and efficiency › Pruning and efficient tuning · approach: Parameter-efficient transfer analysis · 0 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes pMoE, a mixture-of-experts visual prompt tuning method that prompts frozen ViTs from several pre-trained experts (e.g., DINO, MoCo v3, MAE, CLIP, LVM-Med) using expert-specific prompt tokens and a learnable dispatcher that fuses them layer by layer.

Problem

Visual prompt tuning typically draws knowledge from a single pre-trained model, missing potential synergies from integrating diverse general and medical domain experts during adaptation.

Approach

Insert expert-specific prompt tokens for each frozen pre-trained ViT expert and a shared learnable dispatcher that, at each prompt layer, computes softmax weights over all experts' prompt tokens to form integrated prompt tokens for each expert, enabling cross-expert communication while keeping expert-specific patch processing.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Add pMoE to LSPTLSPT on VTAB-1K · VTAB-1K Averageaccuracy: 77.95 -> 80.31Helped
Add pMoE to LSPTLSPT on DINOv2 ViT-B/16 · FGVC (CUB, Flowers, Cars, Dogs, NABirds)accuracy: CUB: 84.85 -> 86.07; Flowers: 95.57 -> 96.58; Cars: 80.63 -> 81.12; Dogs: 84.53 -> 85.17; NABirds: 77.52 -> 78.06Helped
Add pMoE to LSPTLSPT on medical classification · Medical color, X-ray, OCT/CT/MRI datasetsaccuracyHelped
Add pMoE to LSPTLSPT on ADE20K · ADE20K, MAE ViT-B/16mIoU: 39.72 -> 40.68 (SS); 41.51 -> 42.87 (MS)Helped
Add pMoE to LSPTLSPT on medical segmentation · Kvasir-seg and Skin lesionmIoU: Kvasir-seg (MAE): 45.81 -> 47.95; Skin (MAE): 77.63 -> 80.35Helped
Add Expert Prompt Tokens (ablation)pMoE without EPTs or dispatcher · CUBaccuracy: 82.95 -> 83.07Helped
Add dispatcher (ablation)pMoE with EPTs · CUBaccuracy: 83.07 -> 83.38Helped
Use DINO and CLIP experts rather than MoCo v3 and CLIP (ablation)pMoE · CUBaccuracy: 83.38 -> 83.76Helped
Increase dispatcher experts from 3 to 6 (ablation)pMoE · CUBaccuracy: 83.17 -> 83.38Helped
Increase dispatcher experts from 6 to 9 (ablation)pMoE · CUBaccuracy: 83.38 -> 83.43Helped
Increase prompt layers from 3 to 12 (ablation)pMoE · CUBaccuracy: 83.08 -> 83.38Helped
Increase prompt layers from 3 to 12 (ablation)pMoE · NABirdsaccuracy: 76.29 -> 76.73Helped

Limitations

Experimental setup

Datasets: FGVC VTAB-1K Med-VTAB ADE20K Kvasir-seg ISIC skin lesion

Benchmarks: FGVC VTAB-1K Med-VTAB ADE20K Kvasir-seg ISIC

Metrics: accuracy AUC mIoU

Baselines: VPT VPT-Deep GaPT LSPT EXPRES SNF Bi-AdaptFormer

Builds on: Visual Prompt Tuning (VPT) LSPT GaPT EXPRES

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy