Proposes NF-BO, which uses a sequence-specialized autoregressive normalizing flow (SeqFlow) for invertible latent encoding to eliminate the VAE reconstruction gap in latent Bayesian optimization, plus token-level adaptive candidate sampling (TACS) for molecule design.

Problem

Latent Bayesian optimization over discrete sequences (e.g., SELFIES molecules) suffers from a value discrepancy problem: VAE reconstructions do not preserve objective values, so errors propagate through the optimization.

Approach

Replace the VAE with an autoregressive normalizing flow that maps discrete token embeddings to a latent space via an injective embedding lookup (argmax cosine similarity) and an invertible flow, giving exact left-inverse reconstruction; sample local-search candidates by perturbing latent tokens according to PMI-based token importance.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use NF-BO with SeqFlow instead of VAE BOPMO benchmarks, 23 tasks · PMOaverage rank: 19th to 1stHelped
Add TACS to NF-BO (ablation)Guacamol adip, init 1 · Guacamol adip, init 1optimization score: 0.765 ± 0.038 -> 0.818 ± 0.051Helped
Add TACS to NF-BO (ablation)Guacamol med2, init 1 · Guacamol med2, init 1optimization score: 0.306 ± 0.014 -> 0.307 ± 0.027No clear effect
Use SeqFlow's exact-reconstruction mapping instead of BiLSTM mapping (ablation)NF-BO w/o TACS · Guacamol adipoptimization score: 0.716 ± 0.017 -> 0.778 ± 0.016Helped
Use SeqFlow's exact-reconstruction mapping instead of BiLSTM mapping (ablation)NF-BO w/o TACS · Guacamol med2optimization score: 0.347 ± 0.010 -> 0.372 ± 0.012Helped
Set TACS temperature to 200 instead of removing TACS (ablation)NF-BO · Guacamol, 7 tasksscore sum: 5.495 -> 5.565Helped
Set TACS temperature to 100 instead of removing TACS (ablation)NF-BO · Guacamol, 7 tasksscore sum: 5.495 -> 5.481Hurt
Set TACS temperature to 400 instead of removing TACS (ablation)NF-BO · Guacamol, 7 tasksscore sum: 5.495 -> 5.544Helped
Replace uniform token perturbation with TACS (ablation)NF-BO · Guacamol benchmarksoptimization performanceHelped

Surprising findings

Experimental setup

Datasets: GuacaMol ZINC PMO benchmark

Benchmarks: GuacaMol PMO

Metrics: top-1 score top-10 score top-100 score AUC top-1 AUC top-10 AUC top-100 sum of scores

Baselines: LSBO TuRBO-L W-LBO LOLBO CoBO PG-LBO GP BO VAE BO JT-VAE BO REINVENT Graph GA STONED

Builds on: latent bayesian optimization normalizing flows TuRBO LOLBO TextFlow