atlas

Research map / Label-efficient and robust learning / OOD and anomaly detection

Advancing Out-of-Distribution Detection via Local Neuroplasticity

ICLR 2025 · Label-efficient and robust learning › OOD and anomaly detection · approach: Spurious-aware OOD detection · 0 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes a post-hoc OOD detector that compares activations of a trained Kolmogorov-Arnold Network (KAN) against an untrained copy, exploiting KANs' local spline plasticity, and reports state-of-the-art average AUROC on seven image and tabular medical benchmarks.

Problem

Out-of-distribution detection is hard because no single post-hoc detector performs consistently across near and far OOD datasets, and many methods are sensitive to training set size.

Approach

Uses the local plasticity of spline-based KAN activations: a KAN trained on in-distribution data changes only the spline coefficients near InD inputs, so the difference between trained and untrained activations (median-scored, max-aggregated over k-means partitions of the InD data) separates InD from OOD samples.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use KAN detector instead of NACOOD detection · CIFAR-10 benchmarkAvg Overall AUROC: 93.37 -> 94.12Helped
use KAN detector instead of NACOOD detection · CIFAR-100 benchmarkAvg Overall AUROC: 83.36 -> 83.44Helped
use KAN detector instead of ASHOOD detection · ImageNet-200 FSAvg Overall AUROC: 67.18 -> 71.46Helped
use KAN detector instead of NACOOD detection · ImageNet-1K FSAvg Overall AUROC: 76.28 -> 78.52Helped
use KAN detector instead of KLMOOD detection · eICU AgeAUROC: 51.0 -> 50.5Hurt
reduce partitions from 10 to 1 (ablation)KAN detector · CIFAR-10 benchmarkAUROC: 94.12 -> 46.08Hurt
replace KAN splines with binary histograms (ablation)KAN detector · CIFAR-10 benchmarkAUROC: 94.12 -> 85.29%Hurt
use maximum instead of median scoring (ablation)KAN detector · CIFAR-10 benchmarkAUROC: 94.12 -> 54.99Hurt
replace k-means with DBSCAN partitioning (ablation)KAN detector · CIFAR-10 benchmarkAUROC: 94.12 -> 89.82Hurt
train the KAN for regression to a constant instead of classification (ablation)KAN detector · Image benchmarksAUROC: +0.2%Helped
train the KAN for regression to a constant instead of classification (ablation)KAN detector · Tabular medical benchmarksAUROC: approximately 3% decreaseHurt
increase the number of partitions from 1 to 4 (ablation)KAN detector · FriedmanAUROC: 52.11 -> 69.42Helped

Surprising findings

Limitations

Experimental setup

Datasets: CIFAR-10 CIFAR-100 ImageNet-200 ImageNet-1K eICU CIFAR-10 near OOD TIN MNIST SVHN Textures Places365 SSB-hard

Benchmarks: OpenOOD CIFAR-10 OpenOOD CIFAR-100 OpenOOD ImageNet-200 FS OpenOOD ImageNet-1K FS TabMed eICU Ethnicity TabMed eICU Age TabMed eICU Synthetic OOD

Metrics: AUROC FPR@95

Baselines: OpenMax ODIN MDS RMDS Gram ReAct VIM KNN ASH SHE GEN NAC

Builds on: Kolmogorov-Arnold Networks OpenOOD NAC KNN

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy