atlas

Research map / Vision-language and multimodal / Multimodal LLMs

3D-RAD: A Comprehensive 3D Radiology Med-VQA Dataset with Multi-Temporal Analysis and Diverse Diagnostic Tasks

NeurIPS 2025 · Vision-language and multimodal › Multimodal LLMs · approach: Multimodal LLM benchmarks · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Introduces 3D-RAD, a large-scale 3D chest CT Med-VQA benchmark with six tasks including multi-temporal diagnosis, plus a 136K-sample training set, and shows fine-tuning M3D models on it substantially boosts performance.

Problem

Existing Med-VQA datasets are mostly 2D, have limited task diversity, and lack temporal/longitudinal reasoning, hindering evaluation and training of 3D medical VLMs.

Approach

Builds 3D Med-VQA QA pairs from CT-RATE chest CT scans and reports using templates and GPT-4o-mini generation, with temporal QA derived from multi-phase binary labels, then filters with LLM scoring and human validation; fine-tunes 3D Med-VLMs on the resulting training set.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Fine-tune M3D (Phi3-4B) on 3D-RAD-TM3D (Phi3-4B) · 3D-RAD-Bench: Anomaly DetectionBLEU: 15.06 -> 33.28Helped
Fine-tune M3D (Llama2-7B) on 3D-RAD-TM3D (Llama2-7B) · 3D-RAD-Bench: Image ObservationBLEU: 10.69 -> 31.28Helped
Fine-tune M3D (Phi3-4B) on 3D-RAD-TM3D (Phi3-4B) · 3D-RAD-Bench: Medical ComputationBLEU: 2.55 -> 33.52Helped
Fine-tune M3D (Llama2-7B) on 3D-RAD-TM3D (Llama2-7B) · 3D-RAD-Bench: Existence DetectionAccuracy: 18.00 -> 81.09Helped
Fine-tune M3D (Phi3-4B) on 3D-RAD-TM3D (Phi3-4B) · 3D-RAD-Bench: Static Temporal DiagnosisAccuracy: 25.40 -> 49.30Helped
Fine-tune M3D (Llama2-7B) on 3D-RAD-TM3D (Llama2-7B) · 3D-RAD-Bench: Longitudinal Temporal DiagnosisAccuracy: 24.17 -> 74.78Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Anomaly DetectionBLEU: 21.10 -> 33.28Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Image ObservationBLEU: 20.54 -> 39.66Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Medical ComputationBLEU: 7.01 -> 33.52Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Existence DetectionAccuracy: 80.85 -> 82.43Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Static Temporal DiagnosisAccuracy: 41.17 -> 49.30Helped
Increase training data from 1% to 100% (ablation)M3D (Phi3-4B) · 3D-RAD-Bench: Longitudinal Temporal DiagnosisAccuracy: 61.01 -> 74.77Helped

Surprising findings

Limitations

Experimental setup

Datasets: CT-RATE 3D-RAD-T 3D-RAD-Bench

Benchmarks: 3D-RAD-Bench

Metrics: accuracy BLEU ROUGE BERTScore

Baselines: RadFM M3D (Llama2-7B) M3D (Phi3-4B) OmniV LLaVA-OneVision Qwen2.5-VL Gemma-3 InternVL-3 Gemini-2.0-flash GPT-4.1

Builds on: M3D CT-RATE RadFM

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy