atlas

Research map / Reinforcement learning / Visual and representation RL

SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound

NeurIPS 2025 · Reinforcement learning › Visual and representation RL · approach: Dexterous manipulation transfer · 1 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Introduces SonoGym, a GPU-parallel robotic ultrasound simulator built from TotalSegmentator CT models with model-based and pix2pix-based ultrasound rendering, providing navigation, bone reconstruction, and drilling tasks for PPO, A2C, submodular PPO, safe RL, ACT, and diffusion policy.

Problem

Robot learning for complex robotic ultrasound tasks (anatomy reconstruction and ultrasound-guided orthopedic surgery) is limited by the lack of realistic, efficient simulation environments with ultrasound imaging tied to patient anatomy.

Approach

A scalable parallel simulator that renders ultrasound images from CT-derived 3D models both by physics-based ray-tracing and by a pix2pix GAN trained on paired CT-US data, and packages MDP formulations (POMDP, submodular MDP, state-wise constrained MDP) and expert datasets for RL and IL benchmarking.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add a safety filter to PPO (ablation)PPO on surgery with model-based ultrasound · Surgery MB IDTsafe ratio (%): 99.9 -> 100.0Helped
add a safety filter to PPO (ablation)PPO on surgery with model-based ultrasound · Surgery MB IDTinsertion error (mm): 16.0 -> 13.9Helped
add a safety filter to PPO (ablation)PPO on surgery with model-based ultrasound · Surgery MB ODTside error (mm): 5.66 -> 8.94Hurt
add a safety filter to PPO (ablation)PPO on surgery with learning-based ultrasound · Surgery LB IDTsafe ratio (%): 93.1 -> 95.3Helped
add a safety filter to PPO (ablation)PPO on surgery with learning-based ultrasound · Surgery LB IDTinsertion error (mm): 12.3 -> 11.9Helped
use ACT instead of PPOsurgery with learning-based ultrasound · Surgery LB IDTinsertion error (mm): 12.3 -> 1.62Helped
use ACT instead of PPOsurgery with model-based ultrasound · Surgery MB IDTsafe ratio (%): 99.9 -> 65.9Hurt
train and test on a held-out patient rather than the same patientsurgery PPO with learning-based ultrasound · New patientside error (mm): 5.42 -> 27.3Hurt
train and test on a held-out patient rather than the same patientsurgery PPO with learning-based ultrasound · New patientsafe ratio (%): 93.1 -> 52.86Hurt
use multiple ultrasound simulation networks during trainingnavigation agents · Navigation ODTposition error: less than $16[\text{mm}]$No clear effect
use SAC instead of PPO/A2Cnavigation and surgery agents · Navigation and surgerytask performanceHurt
vary Decision Transformer history, action steps, planning horizon, and learning rateDecision Transformer on surgery · Surgerytask performanceNo clear effect

Surprising findings

Limitations

Experimental setup

Datasets: TotalSegmentator in-house paired CT-ultrasound dataset from 7 ex-vivo spine specimens

Benchmarks: SonoGym navigation SonoGym bone surface reconstruction SonoGym ultrasound-guided surgery

Metrics: LPIPS SSIM PSNR final position error rotation error coverage ratio trajectory length insertion error side error safe ratio

Baselines: PPO A2C PPO + safety filter ACT Diffusion Policy heuristic open-loop trajectory SAC PPO-Lagrangian

Builds on: PPO A2C SafeRPlan Action Chunking Transformer Diffusion Policy pix2pix IsaacLab

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy