atlas

Research map / Image generation / Image restoration

Image Reconstruction Via Autoencoding Sequential Deep Image Prior

NeurIPS 2024 · Image generation › Image restoration · approach: Diffusion priors for denoising and deblurring · 9 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes aSeqDIP, a data-free deep image prior that sequentially updates U-Net weights with an input-adaptive data-consistency loss plus an autoencoding regularizer, reducing noise overfitting for MRI, CT, denoising, inpainting and deblurring.

Problem

Deep Image Prior (DIP) overfits noise because of network overparameterization, so the number of optimization iterations must be carefully chosen; diffusion-based alternatives need large clean training data or pre-trained models.

Approach

Replace the fixed random DIP input with a sequential scheme: each U-Net stage is initialized from the previous one, optimized with data consistency plus an autoencoding term that ties its output to its input, and the input is then updated by a single forward pass, with no input gradient updates.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use aSeqDIP instead of Self-Guided DIPMRI reconstruction · fastMRI 4x and 8xPSNR (dB): 33.6±0.23 -> 34.08±0.41; 30.75±0.25 -> 31.34±0.47Helped
Use aSeqDIP instead of Self-Guided DIPCT reconstruction · AAPM CT 18 and 30 viewsPSNR (dB): 33.95±0.32 -> 34.88±0.36; 31.95±0.32 -> 33.09±0.39Helped
Use aSeqDIP instead of the strongest listed baselineCBSD68 denoising · σ=15 and σ=30PSNR (dB): 31,21±0.26 -> 31.51±0.34; 28.67±0.25 -> 28.97±0.44Helped
Use aSeqDIP instead of DPSCBSD68 in-painting · HIAR=0.1 and 0.25PSNR (dB): 23.9±0.45 -> 24.56±0.45; 22.03±0.36 -> 22.57±0.47Helped
Use aSeqDIP instead of DPSCBSD68 non-linear deblurring · BKSEPSNR (dB): 23.40±0.56 -> 23.89±0.40Helped
Add the autoencoding regularization term (λ=1) rather than disable it (λ=0) (ablation)aSeqDIP · MRI 4x and CT 18 viewsPSNR (dB)Helped
Set λ=1 rather than λ=0.5 or λ=2 (ablation)aSeqDIP · MRI 4xPSNR (dB)Mixed
Use N=2, K=2000 rather than N=1, K=4000 or N=4, K=1000 (NK=4000) (ablation)aSeqDIP · MRI, CT, denoising, and in-paintingPSNR (dB)Helped
Use an autoencoding term rather than omit it (ablation)aSeqDIP · MRI 4x and CT 18 viewsPSNR (dB)Helped
Train a clean-image autoencoder and optimize its input at test time (ablation)MRI reconstruction · fastMRI 4xPSNR (dB)Helped

Surprising findings

Limitations

Experimental setup

Datasets: fastMRI AAPM CBSD68 FFHQ

Benchmarks: fastMRI AAPM CBSD68 FFHQ

Metrics: PSNR SSIM run-time

Baselines: Vanilla DIP Self-Guided DIP ES-DIP Ref-Guided DIP TV-DIP SGLD-DIP Score-MRI MCG DPS Rethinking-DIP

Builds on: Deep Image Prior Self-Guided DIP Score-MRI Manifold Constrained Gradient Diffusion Posterior Sampling

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy