Introduces SR-CACO-2, a public confocal fluorescence microscopy dataset of real LR/HR pairs (scales X2, X4, X8) from Caco-2 cells, and benchmarks 16 SISR methods on it.
Problem
Single-image super-resolution for confocal fluorescence microscopy lacks public datasets with real (not synthetic bicubic) low-resolution and high-resolution image pairs, and it is unclear how well SISR methods handle real microscopy degradation.
Approach
A new dataset of real paired confocal LR (/2, /4, /8) and HR tiles of Caco-2 3D cysts with three fluorescent markers, cropped into 512x512 ROI-only patches with registration, plus a benchmark of 16 SISR methods across four families and ROI-based evaluation.
Key results
- SRCNN reaches PSNR 35.08 (X2), 33.71 (X4) and 29.19 (X8) on ROI averages; post-upsampling and pre-upsampling methods are close, with VDSR and ENLCN best on some scales.
- Bicubic interpolation is outperformed by all benchmarked SISR methods on ROI-only evaluation, but methods still produce smooth outputs lacking accurate HR texture.
- Real LR images differ substantially from bicubic-downsampled LR (noisier, different intensity span), so bicubic-based training is not a substitute for real LR data.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Apply SISR instead of bicubic interpolation | SISR methods on SR-CACO-2 · SR-CACO-2 test, ROI, X2 | PSNR: 32.52 vs 35.32 | Helped |
| Apply SISR instead of bicubic interpolation | SISR methods on SR-CACO-2 · SR-CACO-2 test, ROI, X4 | PSNR: 32.86 vs 34.12 | Helped |
| Apply SISR instead of bicubic interpolation | SISR methods on SR-CACO-2 · SR-CACO-2 test, ROI, X8 | PSNR: 28.49 vs 29.27 | Helped |
| Use L2 + λ SSIM instead of L2 loss only (ablation) | SRCNN · SR-CACO-2 test, CELL2, X2, ROI | PSNR: 33.13 vs 33.42 | Helped |
| Use L2 + λ SSIM instead of L1 loss only (ablation) | SRCNN · SR-CACO-2 test, CELL2, X2, ROI | PSNR: 33.03 vs 33.42 | Helped |
| Use L2 + λ SSIM instead of SSIM loss only (ablation) | SRCNN · SR-CACO-2 test, CELL2, X2, ROI | PSNR: 33.19 vs 33.42 | Helped |
| Use L2 + λ SSIM instead of L1 + λ SSIM (ablation) | SRCNN · SR-CACO-2 test, CELL2, X2, ROI | PSNR: 33.38 vs 33.42 | No clear effect |
Surprising findings
- Bicubic-generated LR images look smoother and preserve cell structure better than real microscope LR images, so they cannot substitute for real LR data.
- Some methods (e.g., SwinIR, GRL) collapse on certain cell channels at X2 on ROI evaluation (PSNR around 24-33), indicating training instability.
Limitations
- Only fixed (dead) Caco-2 cells are imaged, so live-cell dynamics and phototoxicity-relevant conditions are not captured.
- Only three markers from a single cell line; limited biological diversity of protein markers and cell types.
- Limited dataset diversity: no over/under-saturated or dim live-imaging conditions.
Experimental setup
Datasets: SR-CACO-2
Benchmarks: SR-CACO-2
Metrics: PSNR NRMSE SSIM
Baselines: Bicubic SRCNN VDSR DRRN MemNet NLSN DFCAN SwinIR EDSR (LIIF) ENLCN GRL ACT
Builds on: SRCNN VDSR EDSR SwinIR LIIF
Closest papers by meaning
- scSplit: Bringing Severity Cognizance to Image Decomposition in Fluorescence Microscopy (NeurIPS 2025 · similarity 0.86)
- Volume Tells: Dual Cycle-Consistent Diffusion for 3D Fluorescence Microscopy De-noising and Super-Resolution (CVPR 2025 · similarity 0.85)
- SinSR: Diffusion-Based Image Super-Resolution in a Single Step (CVPR 2024 · similarity 0.84)
- Micro-Bench: A Microscopy Benchmark for Vision-Language Understanding (NeurIPS 2024 · similarity 0.83)
- StructSR: Refuse Spurious Details in Real-World Image Super-Resolution (AAAI 2025 · similarity 0.83)
- Efficient Online Training for Zero-Shot Time-Lapse Microscopy Denoising and Super-Resolution (AAAI 2025 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.