Introduces BeatDiff, a lightweight 12-lead heartbeat diffusion prior, and EM-BeatDiff, an MCGDiff-based Monte Carlo EM method that solves ECG inverse problems (artifact removal, missing-lead reconstruction, QT prediction, anomaly detection) without task-specific training.
Problem
Heartbeat morphology analysis is hampered by noise and artifacts, missing leads, and scarce annotated data; the paper targets reconstructing clean 12-lead beat morphology from indirect or partial observations.
Approach
Train a small conditional denoising diffusion model on single-beat 12-lead ECGs and use it as a prior in a Bayesian linear inverse problem, sampling posteriors with sequential Monte Carlo guidance (MCGDiff) and estimating unknown observation parameters jointly via Monte Carlo EM, with no fine-tuning per task.
Key results
- BeatDiff (42 MB, ~160 ms inference) matches or beats SSSD (39 GB-scale model, 75 s inference) on sex-balancing classifier augmentation, e.g., F1 78% vs 76% at F=10%M.
- EM-BeatDiff reduces SSD for baseline wander removal to 0.14 vs 4.37 for DeScoD and achieves AUC 84.82 (MI), 93.06 (LAD), 84.73 (LQT) vs AAE 80.23, 82.69, 70.96.
- Missing-lead reconstruction of V1-6 from limb leads and smartwatch (lead I) task reaches lower SSD than EkGAN (1.03 vs 1.63 on smartwatch) while requiring no task-specific training.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use BeatDiff-generated beats to balance the training data | sex classifier · sex-imbalanced classification, F = 10%M | F1: 76 ± 0 -> 78 ± 0 | Helped |
| use EM-BeatDiff instead of DeScoD for artifact removal | ECG artifact removal · Baseline Wander | SSD: 4.37 ± 8.19 -> 0.14 ± 0.01 | Helped |
| use EM-BeatDiff instead of DeScoD for artifact removal | ECG artifact removal · Electrode Motion | Cos.: 92.73 ± 0.25 -> 95.42 ± 0.19 | Helped |
| use EM-BeatDiff instead of EkGAN for missing-lead reconstruction | ECG missing-lead reconstruction · Smartwatch | SSD: 1.63 ± 0.47 -> 1.03 ± 0.05 | Helped |
| use EM-BeatDiff instead of EkGAN for missing-lead reconstruction | ECG missing-lead reconstruction · Smartwatch | Cos.: 91.33 ± 0.38 -> 86.02 ± 0.99 | Hurt |
| use EM-BeatDiff instead of EkGAN for missing-lead reconstruction | ECG missing-lead reconstruction · V1–6 reconstruction | SSD: 2.10 ± 0.83 -> 1.10 ± 0.06 | Helped |
| use EM-BeatDiff instead of AAE for anomaly detection | ECG anomaly detection · LAD | AUC: 82.69 -> 93.06 ± 0.03 | Helped |
| condition on patient age, sex, and RR (ablation) | BeatDiff · ECG generation | EMD | Helped |
| use a deeper denoiser network (ablation) | BeatDiff · ECG generation | EMD | No clear effect |
| condition MI anomaly detection on QRS rather than limb leads (ablation) | EM-BeatDiff · MI anomaly detection | AUC: 0.842 ± 0.001 -> 0.854 ± 0.001 | Helped |
| condition LAD anomaly detection on QRS rather than limb leads (ablation) | EM-BeatDiff · LAD anomaly detection | AUC: 0.908 ± 0.001 -> 0.927 ± 0.001 | Helped |
| condition LAE anomaly detection on ST rather than limb leads (ablation) | EM-BeatDiff · LAE anomaly detection | AUC: 0.759 ± 0.002 -> 0.790 ± 0.002 | Helped |
Surprising findings
- Generated T-waves under EM-BeatDiff follow the Fridericia QT-RR formula (R2 0.98) without explicitly encoding that relationship during training.
Limitations
- Trained only on healthy ECGs; arrhythmic and pathological generalization is limited.
- Multi-beat 10-second ECG reconstruction is harder and needs larger models and more particles.
- Risk of hallucination; clinical validation not performed.
Experimental setup
Datasets: PhysioNet Challenge ECG dataset MIT-BIH Noise Stress Test database MIT-BIH arrhythmia-derived noise
Benchmarks: PhysioNet Challenge ECG (sex classification) MIT-BIH Noise Stress Test (artifact removal) missing lead reconstruction (smartwatch, V1-6) anomaly detection on MI, LAD, LAE, LQT conditions
Metrics: F1 accuracy AUC SSD MAD cosine similarity EMD R2 for QT OOD score
Baselines: SSSD WGAN DeScoD EkGAN AAE
Builds on: MCGDiff EDM (Karras et al. diffusion preconditioning) Score-based ECG denoising (DeScoD) SSSD ECG generation
Closest papers by meaning
- Region-Disentangled Diffusion Model for High-Fidelity PPG-to-ECG Translation (AAAI 2024 · similarity 0.86)
- Variational Diffusion Posterior Sampling with Midpoint Guidance (ICLR 2025 · similarity 0.84)
- ECHOPulse: ECG Controlled Echocardio-gram Video Generation (ICLR 2025 · similarity 0.84)
- Parallel-Learning of Invariant and Tempo-variant Attributes of Single-Lead Cardiac Signals: PLITA (AAAI 2025 · similarity 0.84)
- Reading Your Heart: Learning ECG Words and Sentences via Pre-training ECG Language Model (ICLR 2025 · similarity 0.84)
- Boosting Masked ECG-Text Auto-Encoders as Discriminative Learners (ICML 2025 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.