Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Use an EBM instead of a β-VAE for jet generation | QCD jet generator · QCD jet generation | JSD (M): 11.0 -> $3.2 \pm 2.0$ | Improved |
| Jointly train the generative EBM with a classifier | EBM anomaly detector · OOD H jet tagging | AUC: $0.794 \pm 0.032$ -> $0.815 \pm 0.018$ | Improved |
| Use the score-function norm instead of energy as the anomaly score | EBM · Top jet tagging | AUC: $0.679 \pm 0.009$ -> $0.628 \pm 0.017$ | Hurt |
| Use the score-function norm instead of energy as the anomaly score | EBM · OOD H jet tagging | AUC: $0.794 \pm 0.032$ -> $0.738 \pm 0.033$ | Hurt |
| Use the score-function norm instead of energy as the anomaly score | EBM-CLF · OOD jet tagging | AUC: $0.703 \pm 0.020$ -> $0.679 \pm 0.040$; $0.815 \pm 0.018$ -> $0.722 \pm 0.028$ | Mixed |
| Reduce the discriminative log-likelihood weight to κ=0.5 (ablation) | EBM-CLF · QCD/W/Top 3-way classification | Top-1 Accuracy: 0.850 -> 0.708 | Hurt |
| Reduce the discriminative log-likelihood weight to κ=0.1 (ablation) | EBM-CLF · QCD/W/Top 3-way classification | Top-1 Accuracy: 0.850 -> 0.679 | Hurt |
| Replace the transformer energy function with an MLP (ablation) | EBM jet generator · QCD jet generation | Generation quality | Hurt |
| Replace Langevin dynamics with Hamiltonian Monte Carlo (ablation) | EBM jet generator · QCD jet generation | JSD (p_T): 24 | Hurt |
| Replace Langevin dynamics with Hamiltonian Monte Carlo (ablation) | EBM jet generator · QCD jet generation | JSD (M): 30 | Hurt |
| Use fewer MCMC steps, 5 or 10 rather than the selected 24 (ablation) | EBM training · QCD jet generation | Training stability | Hurt |
| Increase training MCMC steps to 60 or longer rather than the selected 24 (ablation) | EBM training · QCD jet generation | Generation quality | No clear effect |
Closest papers by meaning
- End-To-End Latent Variational Diffusion Models for Inverse Problems in High Energy Physics (NeurIPS 2023 · similarity 0.85)
- Energy Matching: Unifying Flow Matching and Energy-Based Models for Generative Modeling (NeurIPS 2025 · similarity 0.83)
- Patch Hierarchical Attention Transformers for Efficient Particle Jet Tagging (NeurIPS 2026 · similarity 0.82)
- Lorentz-Equivariant Geometric Algebra Transformers for High-Energy Physics (NeurIPS 2024 · similarity 0.81)
- Energy-Based Modelling for Discrete and Mixed Data via Heat Equations on Structured Spaces (NeurIPS 2024 · similarity 0.81)
- BoltzNCE: Learning likelihoods for Boltzmann Generation with Stochastic Interpolants and Noise Contrastive Estimation (NeurIPS 2025 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.