Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| pretrain on Buildings-900K (zero-shot) versus persistence ensemble | Transformer-L (Gaussian) · real commercial buildings | NRMSE: 16.68 -> 13.31 | Improved |
| pretrain on Buildings-900K (zero-shot) versus persistence ensemble | Transformer-L (Gaussian) · real residential buildings | NRMSE: 77.88 -> 79.34 | Hurt |
| fine-tune pretrained model on 6 months of target building data (ablation) | Transformer-L (Gaussian) · real commercial buildings | NRMSE: 13.03 -> 12.96 | Improved |
| fine-tune pretrained model on target building data (ablation) | Transformer-L (Gaussian) · real residential buildings | NRMSE: 79.43 -> 77.20 | Improved |
| fine-tune pretrained model on target building data (ablation) | Transformer-L (Tokens) · real residential buildings | NRMSE: 94.11 -> 94.53 | Hurt |
| pretrain on Buildings-900K before fine-tuning instead of training from scratch (ablation) | Transformer-L (Gaussian) · real commercial buildings | NRMSE: 37.21 -> 12.96 | Improved |
| pretrained + fine-tuned model versus LightGBM | Transformer-L (Gaussian) · real commercial buildings | NRMSE: 16.02 -> 12.96 | Improved |
| use Gaussian outputs instead of load tokens (ablation) | Transformer-L · real commercial buildings zero-shot | NRMSE: 14.46 -> 13.31 | Improved |
| scale pretraining data from 1K to 100K/900K buildings (ablation) | Transformer-M · real commercial buildings | NRMSE | Improved |
| scale pretraining data (ablation) | Transformer-M · real residential buildings | NRMSE | No clear effect |
| increase model size from M to L (ablation) | Transformer · real commercial buildings | NRMSE | No clear effect |
| fine-tune only the last layer instead of all layers (ablation) | pretrained transformers · real buildings transfer | NRMSE | Hurt |
Closest papers by meaning
- NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling (NeurIPS 2026 · similarity 0.87)
- Building Timeseries Dataset: Empowering Large-Scale Building Analytics (NeurIPS 2024 · similarity 0.87)
- PF∆: A Benchmark Dataset for Power Flow under Load, Generation, and Topology Variations (NeurIPS 2025 · similarity 0.83)
- Revisiting the Generic Transformer: Deconstructing a Strong Baseline for Time Series Foundation Models (NeurIPS 2026 · similarity 0.83)
- ProbTS: Benchmarking Point and Distributional Forecasting across Diverse Prediction Horizons (NeurIPS 2024 · similarity 0.82)
- Sundial: A Family of Highly Capable Time Series Foundation Models (ICML 2025 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.