On the symmetries of the synchronization problem in Cryo-EM: Multi-Frequency Vector Diffusion Maps on the Projective Plane

Gabriele Cesa, Arash Behboodi, Taco Cohen, Max Welling

NeurIPS 2022 · 3D vision › Depth and stereo · approach: Feed-forward 3D reconstruction · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add MFVDM O(2) denoising (L=5) to VDM synchronization (ablation)VDM-based sync · Synthetic cryo-EM, N=5000, SNR=0.12pose correlation: 82.0 (0.69) -> 97.5 (0.22)Improved
add MFVDM O(2) denoising (L=5) to VDM synchronization (ablation)VDM-based sync · Synthetic cryo-EM, N=5000, SNR=0.05pose correlation: 60.1 (1.11) -> 63.4 (1.05)Improved
add MFVDM O(2) denoising (L=5) to VDM synchronization (ablation)VDM-based sync · Synthetic cryo-EM, N=3000, SNR=0.35pose correlation: 99.6 (0.1) -> 99.3 (0.13)No clear effect
raise maximum frequency L from 5 to 10 in O(2) denoising (ablation)VDM-based sync · Synthetic cryo-EM, N=5000, SNR=0.05pose correlation: 63.4 (1.05) -> 63.5 (1.05)No clear effect
raise maximum frequency L from 5 to 10 in O(2) denoising (ablation)CL synchronization · Synthetic cryo-EM, N=5000, SNR=0.05pose correlation: 75.9 (0.77) -> 76.6 (0.75)Mixed
use O(2) instead of SO(2) denoising (L=5) (ablation)CL synchronization · Synthetic cryo-EM, N=5000, SNR=0.05pose correlation: 71.4 (0.87) -> 75.9 (0.77)Improved
use O(2) instead of SO(2) denoising (L=5) (ablation)CL synchronization · RELION refinement, N=5000, SNR=0.05pose correlation: 59.4±11.5 -> 76.4±2.6Improved
use VDM synchronization instead of common lines (None denoising)pose pipeline · RELION refinement, N=5000, SNR=0.05estimated resolution: 6.65±1.49 -> 3.51±0.06Improved
use VDM synchronization instead of common lines (None denoising)pose pipeline · RELION refinement, N=5000, SNR=0.12pose correlation: 76.6 -> 99.9±0.0Improved
use CL instead of VDM synchronizationpose pipeline · Synthetic cryo-EM, N=5000, SNR=0.12pose correlation before refinement: 82.0 (0.69) -> 98.0 (0.20)Improved
use O(2) relative poses instead of SO(2) in MFVDM (ablation)MFVDM · synthetic vector datasetcorrelation of cosine similaritiesImproved
use higher maximum frequency L (multi-frequency) (ablation)MFVDM O(2) · synthetic vector datasetcosine similarity estimationImproved