Measured effects reported in the paper

What was changedWhereMeasuredEffect
add superposed embeddings (SE) (ablation)GDFQ · ImageNet ResNet-50 4w4atop-1 accuracy: 52.12 -> 64.09Improved
add superposed embeddings (SE) (ablation)GDFQ · CIFAR-100 ResNet-20 4w4atop-1 accuracy: 63.39 -> 64.55Improved
add disentanglement mapping (DM) to SE (ablation)GDFQ + SE · ImageNet ResNet-50 4w4atop-1 accuracy: 64.09 -> 66.06Improved
add disentanglement mapping (DM) to SE (ablation)GDFQ + SE · CIFAR-100 ResNet-20 4w4atop-1 accuracy: 64.55 -> 64.76No clear effect
add extracted embedding initialization (EEI) to SE (ablation)GDFQ + SE · CIFAR-100 ResNet-20 4w4atop-1 accuracy: 64.55 -> 65.23Improved
add DM and EEI together to SE (ablation)GDFQ + SE · ImageNet ResNet-50 4w4atop-1 accuracy: 66.06 -> 66.25Improved
freeze embeddings after extracted initialization (no training) (ablation)Qimera · ImageNet ResNet-50 4w4atop-1 accuracy: 66.25 -> 63.20Hurt
apply Mixup-style input mixing on GDFQ samplesGDFQ · ImageNet ResNet-50 4w4atop-1 accuracy: 52.12 -> 59.25Improved
apply Cutmix on GDFQ samplesGDFQ · CIFAR-100 ResNet-20 4w4atop-1 accuracy: 63.39 -> 62.74Hurt
lower generator noise sigma_z from 1.0 to 0.25 (ablation)GDFQ · ImageNet ResNet-50 4w4atop-1 accuracy: 52.12 -> 55.30Improved
raise generator noise sigma_z from 1.0 to 2.0 (ablation)GDFQ · ImageNet ResNet-50 4w4atop-1 accuracy: 52.12 -> 46.14Hurt
use 8 DM layers instead of 1 (ablation)Qimera · CIFAR-100 ResNet-20 4w4atop-1 accuracy: 65.10 -> 64.11Hurt

Later papers that compared with this method

1 later accepted paper reports Qimera as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.