HDformer: A Higher-Dimensional Transformer for Detecting Diabetes Utilizing Long-Range Vascular Signals

AAAI 2024 · Architectures and efficiency › Attention and transformers · approach: Efficient image transformers · 4 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes HDformer, a Swin-based Transformer with Time Square Attention (1D PPG reshaped into 2D tokens) and a gated mixture-of-experts over dynamic patch sizes, to detect diabetes from 10-minute PPG on MIMIC-III.

Problem

Non-invasive diabetes detection from PPG has limited accuracy, and standard Transformers cannot efficiently process long-range (10+ minute) vascular waveforms.

Approach

Time Square Attention groups adjacent 1D PPG samples into 2D tokens with dynamic patch sizes, feeding them to a 2D Transformer (Swin) whose outputs are combined by a gated mixture-of-experts, claiming linear complexity in token count.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
increase 1D input length from 8s to 30s (ablation)Informer · MIMIC-IIIaccuracy: 72.5 -> 74.5Helped
increase 1D input length from 30s to 60s (ablation)Informer · MIMIC-IIIaccuracy: 74.5 -> 68.8Hurt
increase TSA input length from 30s to 10m (ablation)HDformer · MIMIC-IIIaccuracy: 75.1 -> 97.3Helped
replace 1D attention with TSA (ablation)Informer · MIMIC-IIIaccuracy: 72.5 -> 85.6Helped
use patch size 4T instead of T/4 (ablation)HDformer TSA · MIMIC-IIIaccuracy: 77.5 -> 89.1Helped
combine dynamic patch sizes with gated MoE (ablation)HDformer TSA · MIMIC-IIIaccuracy: 89.1 -> 97.3Helped
use 2D image representations instead of numerical tensors (ablation)HDformer TSA · MIMIC-IIIaccuracy: 75.1 -> 62.8Hurt
replace Swin Transformer with ViT (ablation)TSA · MIMIC-IIIaccuracy: 97.3 -> 95.9Hurt
add 256hz sampling to 5m PPG (ablation)HDformer · MIMIC-III diabetes detectionaccuracy: 82.9 -> 86.1Helped
add reconstructed ECG multimodal input to 5m, 256hz PPG (ablation)HDformer · MIMIC-III diabetes detectionaccuracy: 86.1 -> 95.1Helped

Surprising findings

Limitations

Experimental setup

Datasets: MIMIC-III Liang et al. 2018 diabetes dataset

Benchmarks: MIMIC-III

Metrics: sensitivity accuracy specificity AUC

Baselines: Moreno et al. 2016 Reddy et al. 2017 Hettiarachchi and Chitraranjan 2019 Qawqzeh et al. 2020 Avram et al. 2020 Wang et al. 2020a Srinivasan and Foroozan 2021 Informer ViT

Builds on: Swin Transformer Vision Transformer Informer mixture-of-experts