atlas

Research map / Label-efficient and robust learning / Domain adaptation and generalization

CLDA: Contrastive Learning for Semi-Supervised Domain Adaptation

NeurIPS 2021 · Label-efficient and robust learning › Domain adaptation and generalization · approach: Feature alignment for unsupervised adaptation · 12 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
combine class-centroid Inter-Domain Contrastive Alignment and instance-level Instance Contrastive Alignment (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 68.3 and 67.7 -> 72.4Helped
add Instance Contrastive Alignment (ablation)CLDA without Instance Contrastive Alignment · Office-Home, Pr→Ar, 3-shottest accuracy: 68.3 -> 72.4Helped
add Inter-Domain Contrastive Alignment (ablation)CLDA without Inter-Domain Contrastive Alignment · Office-Home, Pr→Ar, 3-shottest accuracy: 67.7 -> 72.4Helped
replace Instance Contrastive Alignment with FixMatch (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 70.8 vs 72.4Hurt
replace Instance Contrastive Alignment with L1 consistency loss (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 69.4 vs 72.4Hurt
replace Instance Contrastive Alignment with L2 consistency loss (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 69.3 vs 72.4Hurt
replace model-prediction pseudo-labels with K-means pseudo-labels (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 72.4% -> 71.2%Hurt
set α to 1 instead of 4 (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 72.4% -> 70.7%Hurt
increase β (ablation)CLDA · Office-Home, Pr→Ar, 3-shotvalidation and test accuracyHurt
increase the unlabeled-to-labeled minibatch ratio μ up to 4 (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracyHelped
increase μ beyond 4 (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracyHurt
use RandAugment with Grayscale instead of horizontal flipping (ablation)CLDA · Office-Home, Pr→Ar, 3-shottest accuracy: 68.1 -> 72.4Helped

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy