atlas

Research map / Probabilistic and scientific modeling / Molecules and proteins

From Hope to Safety: Unlearning Biases of Deep Models via Gradient Penalization in Latent Space

AAAI 2024 · Probabilistic and scientific modeling › Molecules and proteins · approach: Neuro-symbolic probabilistic layers · 9 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes RR-CLARC, which post-hoc unlearns latent concept biases by explicitly penalizing the output gradient along a signal-CAV direction, and shows that regression-based CAVs (e.g., SVM) diverge from the true concept direction.

Problem

Deep networks learn spurious correlations (Clever Hans shortcuts) that bias predictions; existing post-hoc correction either needs pixel-level annotations (only for localized biases) or only augments latent activations without explicitly removing bias sensitivity. Also, CAVs from regression solvers

Approach

Compute a robust bias direction with a correlation-based signal-CAV, then fine-tune with a loss that squares the latent gradient of the (optionally class-weighted) output along that direction, explicitly reducing bias sensitivity; the feature extractor up to the CAV layer is frozen so the direction stays fixed.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use RRCLARC instead of the vanilla modelVGG-16 · Bone Age biased test setaccuracy: 49.8 -> 77.7Helped
Use RRCLARC instead of the vanilla modelVGG-16 · ISIC biased test setaccuracy: 34.9 -> 57.0Helped
Use RRCLARC instead of the vanilla modelVGG-16 · ImageNet biased test setaccuracy: 43.5 -> 62.6Helped
Use RRCLARC instead of the vanilla modelVGG-16 · CelebA biased test setaccuracy: 82.8 -> 92.6Helped
Use signal-CAV instead of regression-based CAV optimizers (ablation)RRCLARC · Controlled bias experimentsaccuracy on biased test setHelped
Increase regularization strength λ (ablation)RRCLARC · Biased test setsaccuracyMixed
Penalize only the selected class rather than all classes (ablation)RRCLARC · ImageNet clean test set, selected related classesaccuracyHelped
Apply activation-based A-CLARC or P-CLARC rather than class-specific gradient penalizationImageNet correction · ImageNet clean test set, selected related classesaccuracyHurt
Use input-gradient RRR for unlocalized artifactsVGG-16 · Bone Age biased test setaccuracy: 49.8 -> 49.8No clear effect

Surprising findings

Limitations

Experimental setup

Datasets: ISIC2019 Pediatric Bone Age ImageNet CelebA

Benchmarks: ISIC2019 Pediatric Bone Age ImageNet CelebA

Metrics: accuracy on clean test set accuracy on biased test set TCAV score CAV alignment cosine similarity R_bias relevance

Baselines: Vanilla RRR PCLARC ACLARC

Builds on: CLARC Right for the Right Reasons (RRR) TCAV signal-CAV

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy