AI Paper Atlas

Research map / Label-efficient and robust learning / Recognition and long-tail

Uncertainty-Aware Attention for Reliable Interpretation and Prediction

NeurIPS 2018 · Label-efficient and robust learning › Recognition and long-tail · approach: Loss design and classifier theory · 41 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · PhysioNet MortalityAUROC: 0.7652$\pm$ 0.02 -> 0.7827$\pm$ 0.02Helped
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · PhysioNet Stay < 3AUROC: 0.8515$\pm$ 0.02 -> 0.8628$\pm$ 0.02Helped
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · PhysioNet CardiacAUROC: 0.9485$\pm$ 0.01 -> 0.9563$\pm$ 0.01Helped
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · PhysioNet RecoveryAUROC: 0.8830$\pm$ 0.01 -> 0.9049$\pm$ 0.01Helped
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · Pancreatic CancerAUROC: 0.8528$\pm$ 0.01 -> 0.8604$\pm$ 0.01Helped
replace deterministic attention with input-dependent Gaussian attention uncertaintyRETAIN · MIMIC SepsisAUROC: 0.7965$\pm$ 0.01 -> 0.8017$\pm$ 0.01Helped
make attention variance input-dependent rather than input-independent (ablation)UA · PhysioNet MortalityAUROC: 0.7764$\pm$ 0.01 -> 0.7827$\pm$ 0.02Helped
make attention variance input-dependent rather than input-independent (ablation)UA · PhysioNet Stay < 3AUROC: 0.8572$\pm$ 0.02 -> 0.8628$\pm$ 0.02Helped
make attention variance input-dependent rather than input-independent (ablation)UA · PhysioNet CardiacAUROC: 0.9516$\pm$ 0.01 -> 0.9563$\pm$ 0.01Helped
make attention variance input-dependent rather than input-independent (ablation)UA · PhysioNet RecoveryAUROC: 0.8895$\pm$ 0.01 -> 0.9049$\pm$ 0.01Helped
make attention variance input-dependent rather than input-independent (ablation)UA · Pancreatic CancerAUROC: 0.8533$\pm$ 0.03 -> 0.8604$\pm$ 0.01Helped
make attention variance input-dependent rather than input-independent (ablation)UA · MIMIC SepsisAUROC: 0.8019$\pm$ 0.01 -> 0.8017$\pm$ 0.01No clear effect