AI Paper Atlas

Research map / Probabilistic and scientific modeling / Molecules and proteins

Time-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical Time

Bong Gyun Kang, Junyong Ahn, Hyeongrok Han, Sungroh Yoon

ICML 2026 · Probabilistic and scientific modeling › Molecules and proteins · approach: Neural point-process models

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add Pathology-Focused Binning over quantile binning (ablation)full model · MIMIC-III 117 featuresTotal score: 4.713 -> 4.686Improved
add Pathology-Focused Binning over quantile binning (ablation)full model · MIMIC-III IHMAUPRC: 0.583 -> 0.607Improved
add Dual-Calendar RoPE over standard RoPE (ablation)full model · MIMIC-III 117 featuresTotal score: 4.810 -> 4.713Improved
add Dual-Calendar RoPE over standard RoPE (ablation)full model · MIMIC-III IHMAUPRC: 0.519 -> 0.583Improved
add TCF objective over NTP (ablation)model with quantile binning and RoPE · MIMIC-III 117 featuresTotal score: 5.241 -> 4.810Improved
add next-time prediction loss to TCF (ablation)TCF · MIMIC-III (half training steps)Total score: 4.816 -> 4.762Improved
foresee multiple tokens instead of a single next token (ablation)TCF · MIMIC-III (half training steps)Total score: 4.844 -> 4.762Improved
add time conditioning to multi-token foreseeing (ablation)TCF · MIMIC-III (half training steps)Total score: 4.839 -> 4.762Improved
predict multiple future tokens (simple) instead of NTP (ablation)NTP objective · MIMIC-III (half training steps)Total score: 5.054 -> 4.886Improved
use full model instead of MOTORMOTOR · MIMIC-III IHMAUPRC: 0.552 -> 0.607Improved
use full model instead of ETHOS with value sharingETHOS · MIMIC-IV Dec-deathAUPRC: 0.162 -> 0.278Improved
use full model instead of MOTOR on external hospitalMOTOR · eICU IHMAUROC: 0.757 -> 0.786Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy