AI Paper Atlas

Research map / Image generation / Fast diffusion sampling

Plan for Speed: Dilated Scheduling for Masked Diffusion Language Models

Omer Luxembourg, Haim H. Permuter, Eliya Nachmani

ICML 2026 · Image generation › Fast diffusion sampling · approach: Masked diffusion language model decoding · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace self-confidence planner with DUS at 6.4x speedupLLaDA-Instruct-8B · GSM8K, B=32accuracy: 38.74 -> 65.73Improved
replace self-confidence planner with DUS at 10.7x speedupLLaDA-Base-8B · GSM8K, B=64accuracy: 8.04 -> 35.18Improved
replace self-confidence planner with DUSDiffuCoder-Base-7B · HumanEval, B=16pass@1: 6.71 -> 38.41Improved
replace self-confidence planner with DUS at B=8Dream-Instruct-7B · BBH, B=8accuracy: 55.93 -> 54.81Hurt
replace self-confidence planner with DUSLLaDA/Dream models · MMLU-Proaccuracy: +5-9%Improved
use dilated-incremental schedule instead of fixed-k for self-confidence planner (ablation)self-confidence planner · GSM8K 300 samples, LLaDA-Base B=16accuracy: 55.00 -> 49.33Hurt
use dilated-incremental schedule for random planner instead of fixed-k (ablation)random planner · GSM8K 300 samples, LLaDA-Base B=16accuracy: 24.67 -> 43.67Improved
add dilated spacing (DUS) on top of incremental schedule vs. best non-DUS planner (ablation)DUS · GSM8K 300 samples, LLaDA-Instruct B=32accuracy: 53.67 -> 66.67Improved
add dilated spacing post-filter to EB-Sampler (ablation)EB-Sampler gamma=2 · HumanEval, LLaDA-Instruct, B=32accuracy: 24.4 -> 37.8Improved
add dilated spacing post-filter to CB-Sampler (ablation)CB-Sampler tau=0.5 · HumanEval, LLaDA-Instruct, B=32accuracy: 22.6 -> 34.8Improved
add dilated spacing post-filter to adaptive samplers (ablation)EB/CB-Sampler · Table 4 settingsNFE: EB HumanEval NFE 35 -> 59Hurt
use very small block size B=8 with DUS (ablation)DUS · generalaccuracy gainNo clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy