AI Paper Atlas

Research map / Vision-language and multimodal / Human and embodied modeling

UniMedVL: Unifying Medical Multimodal Understanding and Generation through Observation-Knowledge-Analysis

Junzhi Ning, Wei Li, Cheng Tang, Jiashi Lin, Chenglong Ma, Chaoyang Zhang, Jiyao Liu, Ying Chen, Shujian Gao, Yuandong Pu, Huihui Xu, Chenhui Gou and 15 more

ICML 2026 · Vision-language and multimodal › Human and embodied modeling · approach: Medical vision-language models · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add understanding training to generation-only model (ablation)UniMedVL · medical text-to-image (8 modalities, avg)gFID: 108.40 -> 96.29Improved
add generation training to understanding-only model (ablation)UniMedVL (Stage 1) · GMAI-MMBenchaccuracy: 0.505 -> 0.593Improved
add generation training to understanding-only model (ablation)UniMedVL (Stage 1) · PathVQAaccuracy: 0.367 -> 0.365No clear effect
add generation training to understanding-only model (ablation)UniMedVL (Stage 1) · SLAKEaccuracy: 0.548 -> 0.684Improved
use three-stage progressive curriculum instead of one-stage joint training (ablation)UniMedVL · GMAI-MMBenchaccuracy: 0.535 -> 0.608Improved
use three-stage progressive curriculum instead of one-stage joint training (ablation)UniMedVL · medical text-to-image gFIDgFID: 123.48 -> 96.29Improved
add interleaved tasks in Stage 3 (ablation)UniMedVL · medical text-to-image gFIDgFID: 120.04 -> 96.29Improved
add distilled chain-of-thought data to understanding instructions (ablation)UniMedVL (U-only) · PathVQAaccuracy: 0.367 -> 0.453Improved
add caption augmented generation (CAG) (ablation)UniMedVL (G-only) · medical text-to-image gFIDgFID: 118.60 -> 108.40Improved
add high-quality instruction data in Stage 2 (ablation)UniMedVL · SLAKEaccuracy: 0.684 -> 0.742Improved
add interleaved data in Stage 3 (ablation)UniMedVL · OmniMedVQAaccuracy: 0.863 -> 0.858No clear effect
fine-tune FLUX VAE end-to-end on medical images (ablation)UniMedVL · rFID across modalitiesrFIDNo clear effect

Later papers that compared with this method

1 later accepted paper reports UniMedVL as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy