AI Paper Atlas

Research map / Continual learning / Class-incremental

Cross-View Lewis Weight Fusion Empowering Exemplar Replay for Federated Class-Incremental Learning

Zhuang Qi, Ying-Peng Tang, Lei Meng, Xiaoxiao Li, Han Yu, Xiangxu Meng

ICML 2026 · Continual learning › Class-incremental · approach: Exemplar-efficient class-incremental learning

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add cross-view Lewis weight fusion (p=1) (ablation)Re-Fed+ · CIFAR10 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 52.45 -> 56.11Improved
add cross-view Lewis weight fusion (p=1) (ablation)FedCBDR · CIFAR10 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 56.94 -> 60.94Improved
add cross-view Lewis weight fusion (p=1) (ablation)FedCBDR · CIFAR100 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 42.52 -> 43.21Improved
add frequency-aware weighted training on top of CV-LWF (p=1) (ablation)Re-Fed+ · CIFAR10 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 56.11 -> 57.30Improved
add frequency-aware weighted training on top of CV-LWF (p=1) (ablation)FedCBDR · CIFAR10 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 60.94 -> 62.28Improved
add frequency-aware weighted training on top of CV-LWF (p=1) (ablation)FedCBDR · CIFAR100 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 43.21 -> 43.54Improved
use Lewis p=2 instead of p=1 (ablation)Re-Fed+ + CV-LWF · CIFAR10 (5 tasks, 20 clients, beta=0.5)Top-1 accuracy: 56.11 -> 56.40No clear effect
increase views from 2 to 5 (ablation)CLIFR · CIFAR10 (20 clients)Top-1 accuracy: 52.34 -> 54.97Improved
increase views from 5 to 10 (ablation)CLIFR · CIFAR10 (20 clients)Top-1 accuracy: 54.97 -> 51.66Hurt
increase views from 5 to 10 (ablation)CLIFF · CIFAR10 (20 clients)Top-1 accuracy: 56.63 -> 57.67Improved
increase views from 5 to 10 (ablation)CLIFF · CIFAR100 (20 clients)Top-1 accuracy: 44.20 -> 44.28No clear effect
increase number of views from 2 to 10 (selection time) (ablation)CLIFR · CIFAR10 sample selection time (s)time (s): 2.251 -> 6.825Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy