atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

EEG-Language Pretraining for Highly Label-Efficient Clinical Phenotyping

ICML 2025 · Vision-language and multimodal › CLIP and zero-shot · approach: Language models for zero-shot reasoning · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Introduces EEG-language models (ELMs) pretrained on 15k TUEG EEGs paired with clinical reports, using sub-unit alignment with text segmentation, EEG cropping, and a multiple-instance MIL-InfoNCE loss, improving label-efficient pathology detection and enabling zero-shot classification and retrieval.

Problem

Clinical EEG pathology detection suffers from scarce labels, and EEG-report pairs are long, heterogeneous, and temporally unaligned, so standard vision-language contrastive pretraining does not directly apply.

Approach

Align multiple non-overlapping EEG crops with multiple segmented report sections via a MIL-extended InfoNCE (MIL-NCE style, bidirectional positives), with sampled text clusters and a frozen MedCPT text encoder, so the EEG encoder learns from weak, many-to-many EEG-text correspondences.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use multimodal ELM-MIL rather than EEG-only self-supervised pretrainingEEG encoders · TUAB, 1% labeled training databalanced accuracy: 74.99 -> 83.71Helped
Use multimodal ELM-MIL rather than EEG-only self-supervised pretrainingEEG encoders · NMT, 1% labeled training dataAUROC: 65.72 -> 69.49Helped
Use bidirectional alignment with MIL-InfoNCE instead of the tested alternative positive-sample aggregations (ablation)ELM-MIL e,l · EEG retrieval, Top-10accuracy: 3.9, 8.3, 24.7 -> 27.1Helped
Increase positive EEG samples from 2 to 32 (ablation)ELM-MIL e,l · EEG retrieval, Top-10accuracy: 19.8 -> 27.1Helped
Increase positive text samples from 2 to 8 (ablation)ELM-MIL e,l · TUAB linear probe, 100%balanced accuracy: 85.8 -> 87.1Helped
Train ELM e,l with correctly paired reports rather than shuffled reports (ablation)ELM e,l · TUAB pathology detection with few annotationsaccuracyHelped
Shuffle reports between patients during pretraining (ablation)ELM e,l · TUAB linear probingaccuracy: 73.70%, 81.04%, 83.69%Helped
Use ELM e,l rather than ELM l, without a text projection head (ablation)EEG-language pretraining · Report retrievalTop-K accuracyHelped
Use MedCPT rather than BiomedBERT as the language encoder (ablation)ELM e,l · TUAB zero-shotbalanced accuracy: 78.61{ $\pm$2.90} -> 82.58{ $\pm$0.25}Helped
Use MedCPT rather than Bio-ClinicalBERT as the language encoder (ablation)ELM e,l · TUAB zero-shotAUROC: 87.33{ $\pm$0.68} -> 88.37{ $\pm$0.39}Helped

Surprising findings

Limitations

Experimental setup

Datasets: TUEG TUAB NMT TUSZ TUEV TUH EEG Epilepsy Corpus

Benchmarks: TUAB NMT TUSZ TUEV

Metrics: balanced accuracy AUROC top-k retrieval accuracy F1

Baselines: BYOL VICReg ContraWR Relative Positioning Temporal Shuffling CPC LaBraM BIOT CEReBrO SPaRCNet

Builds on: CLIP MIL-NCE M-FLAG VICReg BYOL

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy