AI Paper Atlas

Research map / Detection and segmentation / 3D detection and driving

PolarFormer: Multi-Camera 3D Object Detection with Polar Transformer

Yanqin Jiang, Li Zhang, Zhenwei Miao, Xiatian Zhu, Jin Gao, Weiming Hu, Yu-Gang Jiang

AAAI 2023 · Detection and segmentation › 3D detection and driving · approach: Multi-camera BEV detection · 191 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use Polar features and Polar predictions rather than Cartesian features and predictions (ablation)PolarFormer · nuScenes valmAP: 38.1 -> 39.6Improved
Use Polar features while retaining Cartesian predictions (ablation)PolarFormer · nuScenes valmAP: 38.1 -> 38.5Improved
Decode predictions in Polar rather than Cartesian coordinates (ablation)PolarFormer with Polar features · nuScenes valmAP: 38.5 -> 39.6Improved
Use fixed Sine PE rather than 2D learnable PE (ablation)PolarFormer · nuScenes valmAP: 38.8 -> 39.6Improved
Use fixed Sine PE rather than 3D PE (ablation)PolarFormer · nuScenes valmAP: 38.5 -> 39.6Improved
Add multi-scale Polar BEV representation instead of single-scale (ablation)PolarFormer · nuScenes valmAP: 39.1 -> 39.6Improved
Add multi-scale BEV representation (ablation)Cartesian-feature PolarFormer-CC · nuScenes valmAP: 38.1 -> 38.1No clear effect
Set azimuth resolution to 256 rather than 240 (ablation)PolarFormer · nuScenes valmAP: 38.8 -> 39.6Improved
Set azimuth resolution to 256 rather than 272 (ablation)PolarFormer · nuScenes valmAP: 38.8 -> 39.6Improved
Set radius resolution to 64 rather than 56 (ablation)PolarFormer · nuScenes valmAP: 38.7 -> 39.6Improved
Set radius resolution to 64 rather than 72 (ablation)PolarFormer · nuScenes valmAP: 38.5 -> 39.6Improved
Set radius resolution to 64 rather than 80 (ablation)PolarFormer · nuScenes valmAP: 38.7 -> 39.6Improved

Later papers that compared with this method

4 later accepted papers report PolarFormer as a baseline in their results tables; 4 of them report a better number on most of the results they share with it.

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy